Measurement of Thermally Induced Depolarization in Flashlamp Pumped <111>- and <100>-Oriented Nd:YAG Laser Rods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F25%3A00388397" target="_blank" >RIV/68407700:21340/25:00388397 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1742-6596/3157/1/012014" target="_blank" >https://doi.org/10.1088/1742-6596/3157/1/012014</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/3157/1/012014" target="_blank" >10.1088/1742-6596/3157/1/012014</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Thermally Induced Depolarization in Flashlamp Pumped <111>- and <100>-Oriented Nd:YAG Laser Rods
Popis výsledku v původním jazyce
Crystals with minimal depolarization effects and losses are desired for specific applications to preserve the orientation of the generated radiation polarization. This work presents an experimental method for measuring the depolarization of radiation propagating through flashlamp pumped Nd:YAG laser rods. Two differently oriented Nd:YAG crystal cuts <111> and <100> with the same concentration of Nd3+ ions and the same dimensions were investigated and compared. A passively Q-switched Nd:YAP/Cr:YAG compact laser system that generates linearly polarized radiation at a wavelength of 1078nm was used as a source of diagnostic pulse radiation. The experimental setup presented enables for the sensitive detection of polarization changes. It can serve as a diagnostic and classifying tool for evaluating the crystal quality after growth and processing.
Název v anglickém jazyce
Measurement of Thermally Induced Depolarization in Flashlamp Pumped <111>- and <100>-Oriented Nd:YAG Laser Rods
Popis výsledku anglicky
Crystals with minimal depolarization effects and losses are desired for specific applications to preserve the orientation of the generated radiation polarization. This work presents an experimental method for measuring the depolarization of radiation propagating through flashlamp pumped Nd:YAG laser rods. Two differently oriented Nd:YAG crystal cuts <111> and <100> with the same concentration of Nd3+ ions and the same dimensions were investigated and compared. A passively Q-switched Nd:YAP/Cr:YAG compact laser system that generates linearly polarized radiation at a wavelength of 1078nm was used as a source of diagnostic pulse radiation. The experimental setup presented enables for the sensitive detection of polarization changes. It can serve as a diagnostic and classifying tool for evaluating the crystal quality after growth and processing.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EH23_020%2F0008525" target="_blank" >EH23_020/0008525: Inovativní laserové a scintilační materiály pro moderní aplikace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Development of Materials Science in Research and Education
ISBN
—
ISSN
1742-6588
e-ISSN
1742-6596
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Fyzikální ústav AV ČR
Místo vydání
Praha
Místo konání akce
Pavlov
Datum konání akce
8. 9. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—