Marginal conditions for measuring the light transmission of windows
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21450%2F24%3A00379456" target="_blank" >RIV/68407700:21450/24:00379456 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.5593/sgem2024/6.1/s27.57" target="_blank" >https://doi.org/10.5593/sgem2024/6.1/s27.57</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5593/sgem2024/6.1/s27.57" target="_blank" >10.5593/sgem2024/6.1/s27.57</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Marginal conditions for measuring the light transmission of windows
Popis výsledku v původním jazyce
The aim of the article is to evaluate the criteria and boundary conditions of measurement of light transmission of windows and glazed structures of buildings. The article deals with possible measurement variants and the influence of external boundary conditions on the resulting values of light transmission of windows and glazed structures. Ensuring the correct criteria and boundary conditions of measurement is the basis for ensuring the correct results of the measured values of light transmission. Light transmission defines parameters of glazing of windows and glazed structures of buildings in the area of evaluation of daylight, which is a basic hygiene requirement in rooms with residents. Based on these requirements, a minimum window size is proposed when designing buildings with a connection to the interior and its use. The size of windows influences the architecture design and energy performance of buildings and thus the environmental burden during construction and operation of buildings.
Název v anglickém jazyce
Marginal conditions for measuring the light transmission of windows
Popis výsledku anglicky
The aim of the article is to evaluate the criteria and boundary conditions of measurement of light transmission of windows and glazed structures of buildings. The article deals with possible measurement variants and the influence of external boundary conditions on the resulting values of light transmission of windows and glazed structures. Ensuring the correct criteria and boundary conditions of measurement is the basis for ensuring the correct results of the measured values of light transmission. Light transmission defines parameters of glazing of windows and glazed structures of buildings in the area of evaluation of daylight, which is a basic hygiene requirement in rooms with residents. Based on these requirements, a minimum window size is proposed when designing buildings with a connection to the interior and its use. The size of windows influences the architecture design and energy performance of buildings and thus the environmental burden during construction and operation of buildings.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20103 - Architecture engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 24th International Multidisciplinary Scientific GeoConference SGEM 2024
ISBN
978-619-7603-72-9
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
6
Strana od-do
397-402
Název nakladatele
STEF92 Technology Ltd.
Místo vydání
Sofia
Místo konání akce
Albena
Datum konání akce
29. 6. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce