Broadband Single-Transverse-Mode Fluorescence Sources Based on Ribs Fabricated in Pulsed Laser Deposited Ti:Sapphire Waveguides
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F04%3A00104805" target="_blank" >RIV/68407700:21460/04:00104805 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Broadband Single-Transverse-Mode Fluorescence Sources Based on Ribs Fabricated in Pulsed Laser Deposited Ti:Sapphire Waveguides
Popis výsledku v původním jazyce
Active rib waveguides with depths and widths varying from 3 to 5 ľm and from 9 to 24 ľm, respectively, have been structured by Ar<sup>+</sup>-beam etching in pulsed laser deposited Ti:sapphire layers. Losses in the channel structures were essentially atthe same levels as the unstructured planar waveguide host, therefore suggesting that there is no significant additional contribution to loss from the rib-fabrication procedure. Measurements of the beam-propagation factors, M<sub>x</sub><sup>2</sup> and M<sub>y</sub><sup>2</sup>, indicate single-transverse-mode fluorescence emission. The fluorescence output power was in the order of 300 ľW when the structures were pumped by a 3-W multiline argon laser. These characteristics make the rib structures suitable as light sources for optical coherence tomography applications and facilitate their coupling to the optical fibre interferometers of such systems.
Název v anglickém jazyce
Broadband Single-Transverse-Mode Fluorescence Sources Based on Ribs Fabricated in Pulsed Laser Deposited Ti:Sapphire Waveguides
Popis výsledku anglicky
Active rib waveguides with depths and widths varying from 3 to 5 ľm and from 9 to 24 ľm, respectively, have been structured by Ar<sup>+</sup>-beam etching in pulsed laser deposited Ti:sapphire layers. Losses in the channel structures were essentially atthe same levels as the unstructured planar waveguide host, therefore suggesting that there is no significant additional contribution to loss from the rib-fabrication procedure. Measurements of the beam-propagation factors, M<sub>x</sub><sup>2</sup> and M<sub>y</sub><sup>2</sup>, indicate single-transverse-mode fluorescence emission. The fluorescence output power was in the order of 300 ľW when the structures were pumped by a 3-W multiline argon laser. These characteristics make the rib structures suitable as light sources for optical coherence tomography applications and facilitate their coupling to the optical fibre interferometers of such systems.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Physics A: Materials Science and Processing
ISSN
0947-8396
e-ISSN
—
Svazek periodika
79
Číslo periodika v rámci svazku
4-6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
4
Strana od-do
1195-1198
Kód UT WoS článku
000222766100111