Není k dispozici
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F04%3A12104800" target="_blank" >RIV/68407700:21460/04:12104800 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21640/04:12104800
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Windkessel Model Analysis in MATLAB
Popis výsledku v původním jazyce
The paper describes three various Windkessel models and demonstrates application of MATLAB for mathematical modelling and simulation experiments with the models. Windkessel models are usually used to describe basic properties of a vascular bed and to study relationships among hemodynamic variables in great vessels. Analysis of systemic or pulmonary arterial load described by parameters such as arterial compliance and peripheral resistance is important for example in quantifying effects of vasodilator orvasoconstrictor drugs. A mathematical model of the relationship between blood pressure and flow in aorta and pulmonary artery can be also useful in design, development and functional analysis of a mechanical heart and/or heart/lung machines. We have found that ascending aortic pressure could be predicted much more better from knowledge of aortic flow by means of four-element windkessel than by the three or two element models.
Název v anglickém jazyce
Windkessel Model Analysis in MATLAB
Popis výsledku anglicky
The paper describes three various Windkessel models and demonstrates application of MATLAB for mathematical modelling and simulation experiments with the models. Windkessel models are usually used to describe basic properties of a vascular bed and to study relationships among hemodynamic variables in great vessels. Analysis of systemic or pulmonary arterial load described by parameters such as arterial compliance and peripheral resistance is important for example in quantifying effects of vasodilator orvasoconstrictor drugs. A mathematical model of the relationship between blood pressure and flow in aorta and pulmonary artery can be also useful in design, development and functional analysis of a mechanical heart and/or heart/lung machines. We have found that ascending aortic pressure could be predicted much more better from knowledge of aortic flow by means of four-element windkessel than by the three or two element models.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 10th Conference STUDENT EEICT 2004
ISBN
80-214-2634-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
50-54
Název nakladatele
VUT v Brně,FEKT
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
28. 4. 2004
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—