Model of Cardiovascular Control During Valsalva Maneuver
Popis výsledku v původním jazyce
We developed a physiologically-based model to quantify cardiovascular control during he Valsalva Maneuver. Our mathematical model analyses measured heart rate and peripheral vascular resistance dynamics and takes into account the hemodynamic changes occurring during intra-thoracic and intra-abdominal pressure elevation. Furthermore the model includes simulation ofthe baroreflex and could fit 44 data sets lobtained from 19 healthy subjects with low residual errors. We developed parameters to quantify thetone of sympathetic and parasympathetic discharge on the Icardiovascular system, what gives an insight view on the regulatory processes riggered during the Valsalva Maneuver. Additionally our model predicts left ventricle stroke volume change, baroreceptors firing rate, as well as the duration and strength of each phase of the Valsalva Maneuver.
Název v anglickém jazyce
Model of Cardiovascular Control During Valsalva Maneuver
Popis výsledku anglicky
We developed a physiologically-based model to quantify cardiovascular control during he Valsalva Maneuver. Our mathematical model analyses measured heart rate and peripheral vascular resistance dynamics and takes into account the hemodynamic changes occurring during intra-thoracic and intra-abdominal pressure elevation. Furthermore the model includes simulation ofthe baroreflex and could fit 44 data sets lobtained from 19 healthy subjects with low residual errors. We developed parameters to quantify thetone of sympathetic and parasympathetic discharge on the Icardiovascular system, what gives an insight view on the regulatory processes riggered during the Valsalva Maneuver. Additionally our model predicts left ventricle stroke volume change, baroreceptors firing rate, as well as the duration and strength of each phase of the Valsalva Maneuver.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 9th Intrenational Conference on Information Technology and Applications in Biomedicine
ISBN
978-1-4244-5378-8
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Larnaca
Datum konání akce
5. 11. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—