Diagnostic Chain for Recording Luminescence Space Distribution
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F10%3A00166154" target="_blank" >RIV/68407700:21460/10:00166154 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnostic Chain for Recording Luminescence Space Distribution
Popis výsledku v původním jazyce
In this contribution we present the result of recording of YAG:Ce luminescence making visible the laser beam profile of LTB MNL 100 nitrogen laser with wavelength of 337,1 nm. The lasing is achieved in high-voltage (10-20 kV) high-speed (few-ns) transverse gas discharges in nitrogen, so the beam profile is not homogeneous. Yttrium aluminum garnet activated by cerium was chosen because it is a fast scintillator with excellent mechanical and chemical resistance applicable in vacuum. Maximum emission wavelength of YAG:Ce is 550 nm and decay time is 70 ns. The thickness of scintillation crystal was 0,8 mm. Front illuminated full frame CCD with resolution 4014 x 2684 and with 9 mm pixel size was used as a detector. Luminescence of YAG:Ce excited with energyand length of pulses of 1,4 mJ and 25 ns was recorded. Vertical and horizontal beam profiles were depicted with 30 Hz repetition frequency and 20 s exposure time. Also luminescence excited with single shot in 2 s exposure time was record
Název v anglickém jazyce
Diagnostic Chain for Recording Luminescence Space Distribution
Popis výsledku anglicky
In this contribution we present the result of recording of YAG:Ce luminescence making visible the laser beam profile of LTB MNL 100 nitrogen laser with wavelength of 337,1 nm. The lasing is achieved in high-voltage (10-20 kV) high-speed (few-ns) transverse gas discharges in nitrogen, so the beam profile is not homogeneous. Yttrium aluminum garnet activated by cerium was chosen because it is a fast scintillator with excellent mechanical and chemical resistance applicable in vacuum. Maximum emission wavelength of YAG:Ce is 550 nm and decay time is 70 ns. The thickness of scintillation crystal was 0,8 mm. Front illuminated full frame CCD with resolution 4014 x 2684 and with 9 mm pixel size was used as a detector. Luminescence of YAG:Ce excited with energyand length of pulses of 1,4 mJ and 25 ns was recorded. Vertical and horizontal beam profiles were depicted with 30 Hz repetition frequency and 20 s exposure time. Also luminescence excited with single shot in 2 s exposure time was record
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Workshop 2010
ISBN
978-80-01-04513-8
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
22. 2. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—