Motion Camera System for Measuring Finger Tapping in Parkinson's Disease
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F11%3A00184277" target="_blank" >RIV/68407700:21460/11:00184277 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.springerlink.com/content/978-3-642-23507-8/" target="_blank" >http://www.springerlink.com/content/978-3-642-23507-8/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-642-23508-5" target="_blank" >10.1007/978-3-642-23508-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Motion Camera System for Measuring Finger Tapping in Parkinson's Disease
Popis výsledku v původním jazyce
Parkinson's disease is a degenerative disorder of the central nervous system and is exhibited by disturbances of motor function. The progress of Parkinson's disease is typi-cally documented using the Unified Parkinson's Disease Rating Scale (UPDRS). Oneof the sections of the UPDRS includes finger tapping test. The objectification of the movement's tests needs an accurate measurement tool. We created a contactless 3-dimensional camera capture system with light passive (wire-less) reflexive markers for motion measurement. The system consists of two industrial 60 Hz cameras with IR cutoff filters. The system is easy to use, space-saving, transportable, and needs just personal computer for data processing; appropriate solution in an outpatient clinic. Thesystem provides 3-dimensional spherical or hemispherical markers in real-time.
Název v anglickém jazyce
Motion Camera System for Measuring Finger Tapping in Parkinson's Disease
Popis výsledku anglicky
Parkinson's disease is a degenerative disorder of the central nervous system and is exhibited by disturbances of motor function. The progress of Parkinson's disease is typi-cally documented using the Unified Parkinson's Disease Rating Scale (UPDRS). Oneof the sections of the UPDRS includes finger tapping test. The objectification of the movement's tests needs an accurate measurement tool. We created a contactless 3-dimensional camera capture system with light passive (wire-less) reflexive markers for motion measurement. The system consists of two industrial 60 Hz cameras with IR cutoff filters. The system is easy to use, space-saving, transportable, and needs just personal computer for data processing; appropriate solution in an outpatient clinic. Thesystem provides 3-dimensional spherical or hemispherical markers in real-time.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings
ISBN
978-3-642-23507-8
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
846-849
Název nakladatele
Springer Science+Business Media
Místo vydání
Berlin
Místo konání akce
Budapest
Datum konání akce
14. 9. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—