Noninvasive system for localization of small repolarization changes in the heart
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F12%3A00197915" target="_blank" >RIV/68407700:21460/12:00197915 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Noninvasive system for localization of small repolarization changes in the heart
Popis výsledku v původním jazyce
Novel noninvasive method for localization of areas of myocardium with changed repolarization that can lead to life threatening cardiac arrhythmias is presented. Method is based on multichannel ECG measurement, body surface potential mapping and solving the inverse problem of electrocardiology to find one or two dipoles representing the pathological sources in the heart. Body surface potential mapping system ProCardio-8 using up to 144 active electrodes was used for multichannel ECG measurement. For theinverse calculations, inhomogeneous model of the shape of thorax with lungs and ventricles including cavities was used. Ability of the system to identify selected cardiac pathologies is demonstrated on cases with one or two ischemic foci. In this paper,analysis of existing system and algorithms for cardiac pathology localization is given in detail. Further software development will include ventricular premature beat foci localization.
Název v anglickém jazyce
Noninvasive system for localization of small repolarization changes in the heart
Popis výsledku anglicky
Novel noninvasive method for localization of areas of myocardium with changed repolarization that can lead to life threatening cardiac arrhythmias is presented. Method is based on multichannel ECG measurement, body surface potential mapping and solving the inverse problem of electrocardiology to find one or two dipoles representing the pathological sources in the heart. Body surface potential mapping system ProCardio-8 using up to 144 active electrodes was used for multichannel ECG measurement. For theinverse calculations, inhomogeneous model of the shape of thorax with lungs and ventricles including cavities was used. Ability of the system to identify selected cardiac pathologies is demonstrated on cases with one or two ischemic foci. In this paper,analysis of existing system and algorithms for cardiac pathology localization is given in detail. Further software development will include ventricular premature beat foci localization.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT11532" target="_blank" >NT11532: Hodnocení zdravotnických prostředků</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika
ISSN
0301-5491
e-ISSN
—
Svazek periodika
42
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
7-10
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—