Luminescence properties of nitrogen-vacancy centres in nanodiamond as a function of size
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F12%3A00198278" target="_blank" >RIV/68407700:21460/12:00198278 - isvavai.cz</a>
Výsledek na webu
<a href="http://imbm.fbmi.cvut.cz/soubory/sbornik2012final.pdf" target="_blank" >http://imbm.fbmi.cvut.cz/soubory/sbornik2012final.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Luminescence properties of nitrogen-vacancy centres in nanodiamond as a function of size
Popis výsledku v původním jazyce
Biomedical monitoring using fluorescent nanodiamonds (fND) as cellular marker require specific fND size, depending on the particular application. Fluorescence in fNDs depends not only on the number and type of the colour centres, but for very small ND itis related to the fND size effects. In this work we concentrate on such size dependence of photoluminescence (PL) properties of fNDs (Petráková 2012). Particles used are fNDs of size range from 8 - 120 nm, prepared from Ib synthetic diamond. The size fraction of 8-50 nm fNDs was separated by centrifugation and used for single particles measurements by drop casting. Size distribution was confirmed by atomic force microscopy (AFM) and dynamic light scattering (DLS). AFM/Raman system was used to study single particles. We model mathematically the NV-/NV0 luminescence and discuss luminescence stability of single particles as a function of their size.
Název v anglickém jazyce
Luminescence properties of nitrogen-vacancy centres in nanodiamond as a function of size
Popis výsledku anglicky
Biomedical monitoring using fluorescent nanodiamonds (fND) as cellular marker require specific fND size, depending on the particular application. Fluorescence in fNDs depends not only on the number and type of the colour centres, but for very small ND itis related to the fND size effects. In this work we concentrate on such size dependence of photoluminescence (PL) properties of fNDs (Petráková 2012). Particles used are fNDs of size range from 8 - 120 nm, prepared from Ib synthetic diamond. The size fraction of 8-50 nm fNDs was separated by centrifugation and used for single particles measurements by drop casting. Size distribution was confirmed by atomic force microscopy (AFM) and dynamic light scattering (DLS). AFM/Raman system was used to study single particles. We model mathematically the NV-/NV0 luminescence and discuss luminescence stability of single particles as a function of their size.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LD11078" target="_blank" >LD11078: Nanofotonické zobrazování buněčných struktur v reálném čase pomocí nanodiamantových částic</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Instuments and Methods for Biology and Medicine 2012
ISBN
978-80-01-05119-1
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
78-80
Název nakladatele
Czech Technical University
Místo vydání
Prague
Místo konání akce
Kladno
Datum konání akce
29. 5. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—