Tidal Volume Dependence on the Ventilatory Frequency and Alveolar Compliance in HFOV
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F13%3A00210165" target="_blank" >RIV/68407700:21460/13:00210165 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.degruyter.com/view/j/bmte.2013.58.issue-s1-N/bmt-2013-4329/bmt-2013-4329.xml?rskey=geRT6Y&result=3" target="_blank" >http://www.degruyter.com/view/j/bmte.2013.58.issue-s1-N/bmt-2013-4329/bmt-2013-4329.xml?rskey=geRT6Y&result=3</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/bmt-2013-4329" target="_blank" >10.1515/bmt-2013-4329</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Tidal Volume Dependence on the Ventilatory Frequency and Alveolar Compliance in HFOV
Popis výsledku v původním jazyce
High frequency oscillatory ventilation has limited possibility of monitoring of intrapulmonary parameters. We have measured tidal volume during high frequency oscillatory ventilation by external monitor. The experimental circuit consisted of ventilator 3100 with its patient circuit, lung simulator 5600i and monitor Florian for measuring of tidal volume. Tidal volume was measured for different values of alveolar compliance that were set on the lung simulator. Measurement was repeated for ventilatory frequencies 3, 5, 7 and 10 Hz. Ventilatory parameters were held constant during the experiment. We have found that change of alveolar compliance has minimal effect on the delivered tidal volume.
Název v anglickém jazyce
Tidal Volume Dependence on the Ventilatory Frequency and Alveolar Compliance in HFOV
Popis výsledku anglicky
High frequency oscillatory ventilation has limited possibility of monitoring of intrapulmonary parameters. We have measured tidal volume during high frequency oscillatory ventilation by external monitor. The experimental circuit consisted of ventilator 3100 with its patient circuit, lung simulator 5600i and monitor Florian for measuring of tidal volume. Tidal volume was measured for different values of alveolar compliance that were set on the lung simulator. Measurement was repeated for ventilatory frequencies 3, 5, 7 and 10 Hz. Ventilatory parameters were held constant during the experiment. We have found that change of alveolar compliance has minimal effect on the delivered tidal volume.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedizinische Technik / Biomedical Engineering
ISSN
0013-5585
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
S1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
—
Kód UT WoS článku
000329463600391
EID výsledku v databázi Scopus
—