A feasibility study evaluating innovative in-ear pulse oximetry for unobtrusive cardiovascular homecare monitoring during sleep
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F13%3A00211501" target="_blank" >RIV/68407700:21460/13:00211501 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A feasibility study evaluating innovative in-ear pulse oximetry for unobtrusive cardiovascular homecare monitoring during sleep
Popis výsledku v původním jazyce
In this paper, we present a novel pulseoximetric sensor which can be worn in the ear channel. In previous work, we could demonstrate that measurement of heart rate (HR), arterial oxygen saturation (SpO2) and respiratory related information can be performed with reliable accuracy. Since these results were obtained under laboratory conditions, we now studied the feasibility of a clinical appliance of the sensor system for cardiovascular monitoring during sleep which may allow diagnosis of sleep apnea in future. Therefore, we performed human trials in a sleep laboratory with patients with a clinical suspicion of sleep apnea. The evaluation focus on heart rate and oxygen saturation. Results was compared with standard polysomnography (PSG) measurements anddemonstrate that nocturnal long-term measurement of oxygen saturation and heart rate is possible with sufficient accuracy.
Název v anglickém jazyce
A feasibility study evaluating innovative in-ear pulse oximetry for unobtrusive cardiovascular homecare monitoring during sleep
Popis výsledku anglicky
In this paper, we present a novel pulseoximetric sensor which can be worn in the ear channel. In previous work, we could demonstrate that measurement of heart rate (HR), arterial oxygen saturation (SpO2) and respiratory related information can be performed with reliable accuracy. Since these results were obtained under laboratory conditions, we now studied the feasibility of a clinical appliance of the sensor system for cardiovascular monitoring during sleep which may allow diagnosis of sleep apnea in future. Therefore, we performed human trials in a sleep laboratory with patients with a clinical suspicion of sleep apnea. The evaluation focus on heart rate and oxygen saturation. Results was compared with standard polysomnography (PSG) measurements anddemonstrate that nocturnal long-term measurement of oxygen saturation and heart rate is possible with sufficient accuracy.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE.2.3.20.0092" target="_blank" >EE.2.3.20.0092: Rozvoj výzkumného týmu BIO-OPT-XUV na FBMI ČVUT</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů