Evaluation of muscle length asymmetry using OpenSim SW and bilateral cyclograms
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F13%3A00213803" target="_blank" >RIV/68407700:21460/13:00213803 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of muscle length asymmetry using OpenSim SW and bilateral cyclograms
Popis výsledku v původním jazyce
Nowadays, modern software systems and MoCap systems allow to monitor, in real-time and remotely, the muscle-tendon behavior. The aim of this article is to introduce a possible method of quantification of muscle length asymmetry which can be used for rehabilitation, and also for evaluating the functionality of the artificial muscles, i.e. actuators of prosthesis. A group of healthy children and children with cerebral palsy was measured using a Vicon motion analysis system. The 3D kinematic data were recorded and the OpenSim software system was used to identify the muscle length. The synchronized bilateral cyclograms were created to quantify muscle length asymmetry of the left and right sides of body. In order to quantify the muscle length asymmetry, wehave described and tested method based on the shape of cyclograms. The new technique has never been applied before to study the gait asymmetry and can be used as an additional method for the determination of gait symmetry. 2013 University
Název v anglickém jazyce
Evaluation of muscle length asymmetry using OpenSim SW and bilateral cyclograms
Popis výsledku anglicky
Nowadays, modern software systems and MoCap systems allow to monitor, in real-time and remotely, the muscle-tendon behavior. The aim of this article is to introduce a possible method of quantification of muscle length asymmetry which can be used for rehabilitation, and also for evaluating the functionality of the artificial muscles, i.e. actuators of prosthesis. A group of healthy children and children with cerebral palsy was measured using a Vicon motion analysis system. The 3D kinematic data were recorded and the OpenSim software system was used to identify the muscle length. The synchronized bilateral cyclograms were created to quantify muscle length asymmetry of the left and right sides of body. In order to quantify the muscle length asymmetry, wehave described and tested method based on the shape of cyclograms. The new technique has never been applied before to study the gait asymmetry and can be used as an additional method for the determination of gait symmetry. 2013 University
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20102015002" target="_blank" >VG20102015002: Osobní bezpečnostní dohledový systém pro podporu výcviku a zásahu jednotek IZS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Applied Electronics - 2013 International Conference on Applied Electronics
ISBN
978-80-261-0166-6
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
4
Strana od-do
165-168
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Pilsen
Datum konání akce
10. 9. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—