Flow measuring during neonatal high frequency jet ventilation using orifice plate
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F14%3A00220789" target="_blank" >RIV/68407700:21460/14:00220789 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.degruyter.com/view/j/bmte.2014.59.issue-s1/issue-files/bmte.2014.59.issue-s1.xml" target="_blank" >http://www.degruyter.com/view/j/bmte.2014.59.issue-s1/issue-files/bmte.2014.59.issue-s1.xml</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow measuring during neonatal high frequency jet ventilation using orifice plate
Popis výsledku v původním jazyce
High frequency jet ventilation has limited possibility of monitoring of inspiratory flow esp. tidal volumes. This study is focused for evaluating of orific plate like a flow sensor for neonatal high-frequency jet ventilators. The experimental cir- cuit consisted of neonatal high frequency jet ventilator LifePulse, experimentaly designed orific plate for 3mm ETC, rig- id bottle - test lung and specialized equipment with pressure sensors for simultaneous measurement of pressures in the circuit. Pressuresin the circuit was measured for different values of respiratory rate with or without inplemented orific plate. We have found that oricfic plate has useble for flow monitoring during neonatal HFJV but pressure loss has to be compensated.
Název v anglickém jazyce
Flow measuring during neonatal high frequency jet ventilation using orifice plate
Popis výsledku anglicky
High frequency jet ventilation has limited possibility of monitoring of inspiratory flow esp. tidal volumes. This study is focused for evaluating of orific plate like a flow sensor for neonatal high-frequency jet ventilators. The experimental cir- cuit consisted of neonatal high frequency jet ventilator LifePulse, experimentaly designed orific plate for 3mm ETC, rig- id bottle - test lung and specialized equipment with pressure sensors for simultaneous measurement of pressures in the circuit. Pressuresin the circuit was measured for different values of respiratory rate with or without inplemented orific plate. We have found that oricfic plate has useble for flow monitoring during neonatal HFJV but pressure loss has to be compensated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
48th DGBMT Annual Conference Proceedings
ISBN
—
ISSN
0013-5585
e-ISSN
—
Počet stran výsledku
3
Strana od-do
"S252"-"S254"
Název nakladatele
Walter de Gruyter GmbH & Co. KG
Místo vydání
Berlin
Místo konání akce
Hannover
Datum konání akce
8. 10. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—