Effects of Orifice Plate as a Flow Sensor in an Endotracheal Tube on the Ability of Elimination CO2 during HFJV—Animal Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F21%3A00349998" target="_blank" >RIV/68407700:21460/21:00349998 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/app11094210" target="_blank" >https://doi.org/10.3390/app11094210</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/app11094210" target="_blank" >10.3390/app11094210</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects of Orifice Plate as a Flow Sensor in an Endotracheal Tube on the Ability of Elimination CO2 during HFJV—Animal Study
Popis výsledku v původním jazyce
High-frequency jet ventilators lacking flow monitoring systems, and information about supplied tidal volumes are still missing. This complicates the jet ventilator’s initial setting; at the same time, it complicates the line of the high-frequency ventilation itself. Therefore, an experimental flow sensor (orifice plate) was designed and placed in the ETC (endotracheal tube). Laboratory tests have confirmed the solution’s functionality, but it was necessary to verify the practical applicability for the clinical environment. The experiment shows that the flow sensor is used only for research purposes or when using functional monitoring of chest excursions.
Název v anglickém jazyce
Effects of Orifice Plate as a Flow Sensor in an Endotracheal Tube on the Ability of Elimination CO2 during HFJV—Animal Study
Popis výsledku anglicky
High-frequency jet ventilators lacking flow monitoring systems, and information about supplied tidal volumes are still missing. This complicates the jet ventilator’s initial setting; at the same time, it complicates the line of the high-frequency ventilation itself. Therefore, an experimental flow sensor (orifice plate) was designed and placed in the ETC (endotracheal tube). Laboratory tests have confirmed the solution’s functionality, but it was necessary to verify the practical applicability for the clinical environment. The experiment shows that the flow sensor is used only for research purposes or when using functional monitoring of chest excursions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Sciences
ISSN
2076-3417
e-ISSN
2076-3417
Svazek periodika
11
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
11
Strana od-do
—
Kód UT WoS článku
000649869300001
EID výsledku v databázi Scopus
2-s2.0-85106147484