A comparison of methods using strain gauges to monitor physiological movements on a hospital bed
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F14%3A00221622" target="_blank" >RIV/68407700:21460/14:00221622 - isvavai.cz</a>
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/ap/article/view/AP.2014.54.0352/2157" target="_blank" >https://ojs.cvut.cz/ojs/index.php/ap/article/view/AP.2014.54.0352/2157</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/AP.2014.54.0352" target="_blank" >10.14311/AP.2014.54.0352</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparison of methods using strain gauges to monitor physiological movements on a hospital bed
Popis výsledku v původním jazyce
A comparison is made between two methods for monitoring small movements made by a patient in a horizontal position on a hospital bed. The methods use sensors based on strain gauge bridges configured to measure torsion deformation and sensors based on strain gauge bridges configured to measure the bending deformation of two two-arm brackets. Both methods provide information about the patient?s physiological movements. The methods were tested and compared in order to decide which may be most appropriate for use in clinical practice. The two methods have never been compared before, and the results can be used in developing new methods for monitoring patients.
Název v anglickém jazyce
A comparison of methods using strain gauges to monitor physiological movements on a hospital bed
Popis výsledku anglicky
A comparison is made between two methods for monitoring small movements made by a patient in a horizontal position on a hospital bed. The methods use sensors based on strain gauge bridges configured to measure torsion deformation and sensors based on strain gauge bridges configured to measure the bending deformation of two two-arm brackets. Both methods provide information about the patient?s physiological movements. The methods were tested and compared in order to decide which may be most appropriate for use in clinical practice. The two methods have never been compared before, and the results can be used in developing new methods for monitoring patients.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20102015002" target="_blank" >VG20102015002: Osobní bezpečnostní dohledový systém pro podporu výcviku a zásahu jednotek IZS</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica
ISSN
1210-2709
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
352-357
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—