Noninvasive localization of ectopic ventricular activity using BSPM and different patient torso models
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F15%3A00229681" target="_blank" >RIV/68407700:21460/15:00229681 - isvavai.cz</a>
Výsledek na webu
<a href="http://elnano.kpi.ua/?index&lang=en" target="_blank" >http://elnano.kpi.ua/?index&lang=en</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ELNANO.2015.7146902" target="_blank" >10.1109/ELNANO.2015.7146902</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Noninvasive localization of ectopic ventricular activity using BSPM and different patient torso models
Popis výsledku v původním jazyce
The possibility of noninvasive localization of the focus of ectopic ventricular activity and dependence of its accuracy on the used heart and torso model were examined. Body surface potentials were measured in 62 leads in two patients with idiopathic extrasystoles having the focus in different ventricular regions assessed by intracardiac electrophysiological study. Integral maps over the initial period of the premature ventricular activation and inhomogeneous torso model were used as input for an inverse solution to find noninvasively the focus of the premature activation represented by a single dipole. Three torso models representing the individual patient torso with different fidelity were attempted. The best agreement between the focus positions obtained from the inverse solution and from the electrophysiological study was achieved when the torso and heart model based on whole-torso CT was used. The use of an individually adjusted general torso model and properly positioned heart mo
Název v anglickém jazyce
Noninvasive localization of ectopic ventricular activity using BSPM and different patient torso models
Popis výsledku anglicky
The possibility of noninvasive localization of the focus of ectopic ventricular activity and dependence of its accuracy on the used heart and torso model were examined. Body surface potentials were measured in 62 leads in two patients with idiopathic extrasystoles having the focus in different ventricular regions assessed by intracardiac electrophysiological study. Integral maps over the initial period of the premature ventricular activation and inhomogeneous torso model were used as input for an inverse solution to find noninvasively the focus of the premature activation represented by a single dipole. Three torso models representing the individual patient torso with different fidelity were attempted. The best agreement between the focus positions obtained from the inverse solution and from the electrophysiological study was achieved when the torso and heart model based on whole-torso CT was used. The use of an individually adjusted general torso model and properly positioned heart mo
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE 35th International Conference on Electronics and nanotechnology (ELNANO), 2015
ISBN
9781467365345
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
325-329
Název nakladatele
IEEE
Místo vydání
Piscataway (New Jersey)
Místo konání akce
Kyjev
Datum konání akce
21. 4. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—