The Effect of Dynamic Hypoinflation during High Frequency Oscillatory Ventilation in an in Vitro Model of the Respiratory System
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F15%3A00235154" target="_blank" >RIV/68407700:21460/15:00235154 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7391479" target="_blank" >http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7391479</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EHB.2015.7391479" target="_blank" >10.1109/EHB.2015.7391479</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effect of Dynamic Hypoinflation during High Frequency Oscillatory Ventilation in an in Vitro Model of the Respiratory System
Popis výsledku v původním jazyce
Dynamic hyperinflation during high frequency oscillatory ventilation (HFOV) is defined as a situation when the mean alveolar pressure (mPalv) is higher than the mean airway pressure (mPaw). Lower inspiratory to expiratory time ratio (I:E) is recommendedto prevent dynamic hyperinflation. Some studies document a possibility of the opposite effect-dynamic hypoinflation (mPalv<mPaw). The aim of this study is to investigate whether dynamic hypoinflation may occur during HFOV when a linear or parabolic resistance simulating the airway resistance is present in the model of the respiratory system (RS) and whether the magnitude of the dynamic hypoinflation can be predicted based on the ventilatory parameters and setting of the HFOV ventilator. Models of the RSwith various linear and parabolic resistors were ventilated with SensorMedics 3100B ventilator with various preset parameters. The preset I:E of 1:2 and the presence of a parabolic resistance in the circuit increase the magnitude of the
Název v anglickém jazyce
The Effect of Dynamic Hypoinflation during High Frequency Oscillatory Ventilation in an in Vitro Model of the Respiratory System
Popis výsledku anglicky
Dynamic hyperinflation during high frequency oscillatory ventilation (HFOV) is defined as a situation when the mean alveolar pressure (mPalv) is higher than the mean airway pressure (mPaw). Lower inspiratory to expiratory time ratio (I:E) is recommendedto prevent dynamic hyperinflation. Some studies document a possibility of the opposite effect-dynamic hypoinflation (mPalv<mPaw). The aim of this study is to investigate whether dynamic hypoinflation may occur during HFOV when a linear or parabolic resistance simulating the airway resistance is present in the model of the respiratory system (RS) and whether the magnitude of the dynamic hypoinflation can be predicted based on the ventilatory parameters and setting of the HFOV ventilator. Models of the RSwith various linear and parabolic resistors were ventilated with SensorMedics 3100B ventilator with various preset parameters. The preset I:E of 1:2 and the presence of a parabolic resistance in the circuit increase the magnitude of the
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20102015062" target="_blank" >VG20102015062: Výzkumná podpora HZS ČR a dalších složek IZS ČR</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The 5th IEEE International Conference on E-Health and Bioengineering
ISBN
978-1-4673-7545-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Gr. T. Popa University of Medicine and Pharmacy
Místo vydání
Iasi
Místo konání akce
Iasi
Datum konání akce
19. 11. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—