EFFECT OF INSPIRATORY-TO-EXPIRATORY TIME RATIO AND AMPLITUDE OF OSCILLATIONS ON THE DEVELOPMENT AND MAGNITUDE OF DYNAMIC HYPERINFLATION AND HYPOINFLATION OF LUNGS DURING HFOV
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F22%3A00372280" target="_blank" >RIV/68407700:21460/22:00372280 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.14311/CTJ.2022.2.03" target="_blank" >https://doi.org/10.14311/CTJ.2022.2.03</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CTJ.2022.2.03" target="_blank" >10.14311/CTJ.2022.2.03</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EFFECT OF INSPIRATORY-TO-EXPIRATORY TIME RATIO AND AMPLITUDE OF OSCILLATIONS ON THE DEVELOPMENT AND MAGNITUDE OF DYNAMIC HYPERINFLATION AND HYPOINFLATION OF LUNGS DURING HFOV
Popis výsledku v původním jazyce
During high-frequency oscillatory ventilation (HFOV), a situation may occur where the mean alveolar pressure (mPalv) differs significantly from the mean airway pressure (mPaw). Studies documenting the differences between these pressures during HFOV have documented states of both higher and lower mPalv compared to mPaw. The effect of HFOV parameters on the pressure difference is not yet understood. The aim of this study is to investigate how this phenomenon is affected by the ratio of inspiratory to expiratory time and the amplitude of HFOV oscillations (ΔP). The effect of the listed ventilation parameters was investigated in vitro in seven laboratory models and in vivo on nine pigs. The study found that an inspiratory to expiratory time ratio of 1:1 always results in a positive pressure difference between mPalv and mPaw, referred to as dynamic hyperinflation. At an inspiratory to expiratory ratio of 1:2 this pressure difference is negative in the majority of in vitro models of the respiratory system and in all animals. In addition, the study found that the magnitude of the pressure difference is affected by the ΔP. There is a critical value of ΔP at which the trend of the pressure gradient between the alveolar space and the airways is reversed in relation to the oscillation amplitude.
Název v anglickém jazyce
EFFECT OF INSPIRATORY-TO-EXPIRATORY TIME RATIO AND AMPLITUDE OF OSCILLATIONS ON THE DEVELOPMENT AND MAGNITUDE OF DYNAMIC HYPERINFLATION AND HYPOINFLATION OF LUNGS DURING HFOV
Popis výsledku anglicky
During high-frequency oscillatory ventilation (HFOV), a situation may occur where the mean alveolar pressure (mPalv) differs significantly from the mean airway pressure (mPaw). Studies documenting the differences between these pressures during HFOV have documented states of both higher and lower mPalv compared to mPaw. The effect of HFOV parameters on the pressure difference is not yet understood. The aim of this study is to investigate how this phenomenon is affected by the ratio of inspiratory to expiratory time and the amplitude of HFOV oscillations (ΔP). The effect of the listed ventilation parameters was investigated in vitro in seven laboratory models and in vivo on nine pigs. The study found that an inspiratory to expiratory time ratio of 1:1 always results in a positive pressure difference between mPalv and mPaw, referred to as dynamic hyperinflation. At an inspiratory to expiratory ratio of 1:2 this pressure difference is negative in the majority of in vitro models of the respiratory system and in all animals. In addition, the study found that the magnitude of the pressure difference is affected by the ΔP. There is a critical value of ΔP at which the trend of the pressure gradient between the alveolar space and the airways is reversed in relation to the oscillation amplitude.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika – Clinician and Technology
ISSN
0301-5491
e-ISSN
2336-5552
Svazek periodika
52
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
48-54
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85163319282