Accuracy of noninvasive PVC focus localization depending on its position in the ventricles: A simulation study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F17%3A00315502" target="_blank" >RIV/68407700:21460/17:00315502 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.23919/MEASUREMENT.2017.7983573" target="_blank" >http://dx.doi.org/10.23919/MEASUREMENT.2017.7983573</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23919/MEASUREMENT.2017.7983573" target="_blank" >10.23919/MEASUREMENT.2017.7983573</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Accuracy of noninvasive PVC focus localization depending on its position in the ventricles: A simulation study
Popis výsledku v původním jazyce
Noninvasive localization of the foci of premature ventricular contractions (PVCs) was performed in a simulation study using ECGSim software. Single dipole model was used to represent the heart generator and to solve the inverse problem of electrocardiography. Integral body surface potential maps computed from 64 chest leads and inhomogeneous torso model were used as input data for the inverse solution. The accuracy of the PVC localization was evaluated for forty PVC positions located in eight segments in both, right and left ventricle. The mean localization errors of PVC foci in segments of the left ventricle were smaller than for segments in the right ventricle. The best result was achieved for anterior segment of the left ventricle, while the worst one was obtained for the anterior segment in the right ventricle.
Název v anglickém jazyce
Accuracy of noninvasive PVC focus localization depending on its position in the ventricles: A simulation study
Popis výsledku anglicky
Noninvasive localization of the foci of premature ventricular contractions (PVCs) was performed in a simulation study using ECGSim software. Single dipole model was used to represent the heart generator and to solve the inverse problem of electrocardiography. Integral body surface potential maps computed from 64 chest leads and inhomogeneous torso model were used as input data for the inverse solution. The accuracy of the PVC localization was evaluated for forty PVC positions located in eight segments in both, right and left ventricle. The mean localization errors of PVC foci in segments of the left ventricle were smaller than for segments in the right ventricle. The best result was achieved for anterior segment of the left ventricle, while the worst one was obtained for the anterior segment in the right ventricle.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MEASUREMENT 2017
ISBN
9788097262914
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
209-212
Název nakladatele
Institute of Measurement Science of the SAS
Místo vydání
Bratislava
Místo konání akce
Smolenice
Datum konání akce
29. 5. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—