Effects of a change in the direction of view to near uncorrected visual acuity following implantation of monofocal intraocular lens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F19%3A00331060" target="_blank" >RIV/68407700:21460/19:00331060 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3892/br.2019.1203" target="_blank" >https://doi.org/10.3892/br.2019.1203</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3892/br.2019.1203" target="_blank" >10.3892/br.2019.1203</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects of a change in the direction of view to near uncorrected visual acuity following implantation of monofocal intraocular lens
Popis výsledku v původním jazyce
The objective of the present study was to evaluate the effect of the direction of view of the eye on the postoperative near visual acuity of patients with monofocal intraocular lens. A total of 121 eyes in which we performed conventional cataract surgery with implantation of a monofocal lens were included in the study group. The postoperative examination of near visual acuity was performed at two different positions of the eye at a constant distance from the reading table, with the assumption of improving visual acuity when looking perpendicularly to the plane of the floor. The mutual relation of the postoperative parameters central keratometry (Kc), keratometry in the visual axis (KVA) and anterior chamber depth (ACD) for the single axial length ranges was determined using the correlation coefficients. In the case of vertical position of the eye (visual axis of the eye perpendicular to the floor), the uncorrected visual acuity following implantation of the monofocal lens was higher or equal compared to the horizontal position of the eye (visual axis of the eye parallel to the floor). The mean visual acuity at the horizontal position of the eye was 0.508 according to Jaeger's tables (P<0.001); at the vertical position, the mean value was 0.555 (P<0.001). Within the entire group, a weak association at best was observed between the postoperative parameters (Kc, KVA and ACD) and subsequent near visual acuity.
Název v anglickém jazyce
Effects of a change in the direction of view to near uncorrected visual acuity following implantation of monofocal intraocular lens
Popis výsledku anglicky
The objective of the present study was to evaluate the effect of the direction of view of the eye on the postoperative near visual acuity of patients with monofocal intraocular lens. A total of 121 eyes in which we performed conventional cataract surgery with implantation of a monofocal lens were included in the study group. The postoperative examination of near visual acuity was performed at two different positions of the eye at a constant distance from the reading table, with the assumption of improving visual acuity when looking perpendicularly to the plane of the floor. The mutual relation of the postoperative parameters central keratometry (Kc), keratometry in the visual axis (KVA) and anterior chamber depth (ACD) for the single axial length ranges was determined using the correlation coefficients. In the case of vertical position of the eye (visual axis of the eye perpendicular to the floor), the uncorrected visual acuity following implantation of the monofocal lens was higher or equal compared to the horizontal position of the eye (visual axis of the eye parallel to the floor). The mean visual acuity at the horizontal position of the eye was 0.508 according to Jaeger's tables (P<0.001); at the vertical position, the mean value was 0.555 (P<0.001). Within the entire group, a weak association at best was observed between the postoperative parameters (Kc, KVA and ACD) and subsequent near visual acuity.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Reports
ISSN
2049-9434
e-ISSN
2049-9442
Svazek periodika
10
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
271-276
Kód UT WoS článku
000466548000001
EID výsledku v databázi Scopus
2-s2.0-85070252330