Low Dose Bath from IMPT Vs. IMXT for the Pelvic Area when Treating Advanced Prostate Cancer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F19%3A00349473" target="_blank" >RIV/68407700:21460/19:00349473 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1093/rpd/ncz235" target="_blank" >https://doi.org/10.1093/rpd/ncz235</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz235" target="_blank" >10.1093/rpd/ncz235</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Low Dose Bath from IMPT Vs. IMXT for the Pelvic Area when Treating Advanced Prostate Cancer
Popis výsledku v původním jazyce
Twenty (10 intensity-modulated proton therapy (IMPT) and 10 intensity-modulated x-ray therapy (IMXT) treatment plans for patients with advanced prostate carcinoma were compared in this study. All chosen patients were indicated for prostate and pelvic lymph nodes irradiation using simultaneous integrated boost technique. These patients represent typical specimen for this diagnose. IMPT irradiates just half of the tissue volume with a low dose (up to 10 cobalt gray equivalent) compared to IMXT without compromise in target volumes coverage and in this way reduces the risk of secondary cancer development or other possible complications.
Název v anglickém jazyce
Low Dose Bath from IMPT Vs. IMXT for the Pelvic Area when Treating Advanced Prostate Cancer
Popis výsledku anglicky
Twenty (10 intensity-modulated proton therapy (IMPT) and 10 intensity-modulated x-ray therapy (IMXT) treatment plans for patients with advanced prostate carcinoma were compared in this study. All chosen patients were indicated for prostate and pelvic lymph nodes irradiation using simultaneous integrated boost technique. These patients represent typical specimen for this diagnose. IMPT irradiates just half of the tissue volume with a low dose (up to 10 cobalt gray equivalent) compared to IMXT without compromise in target volumes coverage and in this way reduces the risk of secondary cancer development or other possible complications.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
377-380
Kód UT WoS článku
000530582200047
EID výsledku v databázi Scopus
2-s2.0-85082779703