Oct angiography and doppler ultrasound in hypertension glaucoma
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F21%3A00351177" target="_blank" >RIV/68407700:21460/21:00351177 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.31348/2021/15" target="_blank" >https://doi.org/10.31348/2021/15</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.31348/2021/15" target="_blank" >10.31348/2021/15</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Oct angiography and doppler ultrasound in hypertension glaucoma
Popis výsledku v původním jazyce
The main aim of this work was to find out if there is a correlation between vessel density (VD) and results of measured perfusion values in ophthalmic artery and in central retinal artery of the same eye in a group with hypertension glaucoma (HTG). Criteria for inclusion in the study: visual acuity 1,0 with possible correction less than ±3 diopters, approximately the same changes in visual fields in every patient, intraocular pressure (IOP) less than 18 mmHg, no other ocular or neurological diseases. VD was measured by Avanti RTVue XR by Optovue firm, perfusion parameters were measured using Doppler ultrasound with Affinity 70G machine by Philips firm. The peak systolic velocity (PSV) and end diastolic velocity (EDV) and resistance index (RI) were measured both in ophthalmic artery (AO) and in central retinal artery (CRA). Visual field (VF) was examined by quick threshold glaucoma program by Medmont M 700 machine. The sum of sensitivities in apostilbs (abs) was evaluated in the range 0–22 degrees of visual field. The results of sensitivities in visual field were compared to VD and perfusion parameters in CRA and AO of the same eye. Results: Pearson’s correlation coefficient (p = 0,05) was used to assess the dependency between chosen parameters. By comparing VF and VD from measured areas, strong correlation was revealed. It was then proved that VD (WI-VDs) correlates with RICRA weakly (r = -0.35) and moderately strongly (WI-VDa r = -0.4, PP-VDs r = -0.43 and PP-VDa r = -0.45). This means that with increasing resistance index in CRA the density in VD decreases. The other correlations between VD and perfusion parameters (PSV and EDV) in CRA and AO were not significant. Measured values showed that the vascular component of VD has a huge impact on the changes in visual fields in HTG. Weak to moderate influence exists between VD and RI in CRA. OCTA has proven to be more suitable than Doppler ultrasound for determining the condition of blood circulation in the eye.
Název v anglickém jazyce
Oct angiography and doppler ultrasound in hypertension glaucoma
Popis výsledku anglicky
The main aim of this work was to find out if there is a correlation between vessel density (VD) and results of measured perfusion values in ophthalmic artery and in central retinal artery of the same eye in a group with hypertension glaucoma (HTG). Criteria for inclusion in the study: visual acuity 1,0 with possible correction less than ±3 diopters, approximately the same changes in visual fields in every patient, intraocular pressure (IOP) less than 18 mmHg, no other ocular or neurological diseases. VD was measured by Avanti RTVue XR by Optovue firm, perfusion parameters were measured using Doppler ultrasound with Affinity 70G machine by Philips firm. The peak systolic velocity (PSV) and end diastolic velocity (EDV) and resistance index (RI) were measured both in ophthalmic artery (AO) and in central retinal artery (CRA). Visual field (VF) was examined by quick threshold glaucoma program by Medmont M 700 machine. The sum of sensitivities in apostilbs (abs) was evaluated in the range 0–22 degrees of visual field. The results of sensitivities in visual field were compared to VD and perfusion parameters in CRA and AO of the same eye. Results: Pearson’s correlation coefficient (p = 0,05) was used to assess the dependency between chosen parameters. By comparing VF and VD from measured areas, strong correlation was revealed. It was then proved that VD (WI-VDs) correlates with RICRA weakly (r = -0.35) and moderately strongly (WI-VDa r = -0.4, PP-VDs r = -0.43 and PP-VDa r = -0.45). This means that with increasing resistance index in CRA the density in VD decreases. The other correlations between VD and perfusion parameters (PSV and EDV) in CRA and AO were not significant. Measured values showed that the vascular component of VD has a huge impact on the changes in visual fields in HTG. Weak to moderate influence exists between VD and RI in CRA. OCTA has proven to be more suitable than Doppler ultrasound for determining the condition of blood circulation in the eye.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ceska a Slovenska Oftalmologie
ISSN
1211-9059
e-ISSN
—
Svazek periodika
77
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
133-136
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85109862701