OCTA and Doppler Ultrasound in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F23%3A00366050" target="_blank" >RIV/68407700:21460/23:00366050 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/life13030610" target="_blank" >https://doi.org/10.3390/life13030610</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/life13030610" target="_blank" >10.3390/life13030610</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
OCTA and Doppler Ultrasound in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma
Popis výsledku v původním jazyce
The aim of this study was to determine whether the values of vessel density (VD) and perfusion parameters in the ophthalmic artery (OA) and central retinal artery (CRA) of the same eye differ in patients with hypertensive glaucoma (HTG) from patients with normotensive glaucoma (NTG). The first group consisted of 20 HTG patients (40 eyes). Patients with HTG were verified to have primary open-angle glaucoma (POAG). The second group consisted of 20 HTG patients (40 eyes). VD was used to determine the Avanti RTVue XR from Optovue (USA). Peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistance index (RI) were measured in both the central retinal artery (CRA) and ophthalmic artery (OA) using Doppler sonography on the Affinity 70G from Philips (USA). The visual field (VF) was examined by a fast threshold glaucoma program using a Medmont M700 (Australia). We showed no differences in VF, VD, PSV-OA and EDV-CRA between the two groups. Statistically significant differences between the two groups were observed in PSV in CRA (p = 0.04), EDV in OA (p = 0.009) and in RI in both CRA and OA. Other values were without significant differences in both groups. In both HTG and NTG, we observed in PSV-CRA, EDV-OA, RI-CRA and RI-OA.
Název v anglickém jazyce
OCTA and Doppler Ultrasound in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma
Popis výsledku anglicky
The aim of this study was to determine whether the values of vessel density (VD) and perfusion parameters in the ophthalmic artery (OA) and central retinal artery (CRA) of the same eye differ in patients with hypertensive glaucoma (HTG) from patients with normotensive glaucoma (NTG). The first group consisted of 20 HTG patients (40 eyes). Patients with HTG were verified to have primary open-angle glaucoma (POAG). The second group consisted of 20 HTG patients (40 eyes). VD was used to determine the Avanti RTVue XR from Optovue (USA). Peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistance index (RI) were measured in both the central retinal artery (CRA) and ophthalmic artery (OA) using Doppler sonography on the Affinity 70G from Philips (USA). The visual field (VF) was examined by a fast threshold glaucoma program using a Medmont M700 (Australia). We showed no differences in VF, VD, PSV-OA and EDV-CRA between the two groups. Statistically significant differences between the two groups were observed in PSV in CRA (p = 0.04), EDV in OA (p = 0.009) and in RI in both CRA and OA. Other values were without significant differences in both groups. In both HTG and NTG, we observed in PSV-CRA, EDV-OA, RI-CRA and RI-OA.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Life
ISSN
2075-1729
e-ISSN
—
Svazek periodika
3
Číslo periodika v rámci svazku
13
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000958012300001
EID výsledku v databázi Scopus
2-s2.0-85152701094