Automated Oxygen Delivery in Neonatal Intensive Care
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F22%3A00359428" target="_blank" >RIV/68407700:21460/22:00359428 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3389/fped.2022.915312" target="_blank" >https://doi.org/10.3389/fped.2022.915312</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fped.2022.915312" target="_blank" >10.3389/fped.2022.915312</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automated Oxygen Delivery in Neonatal Intensive Care
Popis výsledku v původním jazyce
Oxygen is the most common drug used in the neonatal intensive care. It has a narrow therapeutic range in preterm infants. Too high (hyperoxemia) or low oxygen (hypoxemia) is associated with adverse neonatal outcomes. It is not only prudent to maintain oxygen saturations in the target range, but also to avoid extremes of oxygen saturations. In routine practice when done manually by the staff, it is challenging to maintain oxygen saturations within the target range. Automatic control of oxygen delivery is now feasible and has shown to improve the time spent with in the target range of oxygen saturations. In addition, it also helps to avoid extremes of oxygen saturation. However, there are no studies that evaluated the clinical outcomes with automatic control of oxygen delivery. In this narrative review article, we aim to present the current evidence on automatic oxygen control and the future directions.
Název v anglickém jazyce
Automated Oxygen Delivery in Neonatal Intensive Care
Popis výsledku anglicky
Oxygen is the most common drug used in the neonatal intensive care. It has a narrow therapeutic range in preterm infants. Too high (hyperoxemia) or low oxygen (hypoxemia) is associated with adverse neonatal outcomes. It is not only prudent to maintain oxygen saturations in the target range, but also to avoid extremes of oxygen saturations. In routine practice when done manually by the staff, it is challenging to maintain oxygen saturations within the target range. Automatic control of oxygen delivery is now feasible and has shown to improve the time spent with in the target range of oxygen saturations. In addition, it also helps to avoid extremes of oxygen saturation. However, there are no studies that evaluated the clinical outcomes with automatic control of oxygen delivery. In this narrative review article, we aim to present the current evidence on automatic oxygen control and the future directions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frontiers in Pediatrics
ISSN
2296-2360
e-ISSN
2296-2360
Svazek periodika
10
Číslo periodika v rámci svazku
915312
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000821279700001
EID výsledku v databázi Scopus
2-s2.0-85133691151