The Relationship Between the Thickness of cpRNFL in Segments and Intraocular Pressure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F22%3A00360875" target="_blank" >RIV/68407700:21460/22:00360875 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.2147/OPTH.S388936" target="_blank" >https://doi.org/10.2147/OPTH.S388936</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2147/OPTH.S388936" target="_blank" >10.2147/OPTH.S388936</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Relationship Between the Thickness of cpRNFL in Segments and Intraocular Pressure
Popis výsledku v původním jazyce
Purpose: The aim of this study was to investigate whether the retinal nerve fibre layer (RNFL) in some segments of the optic nerve disc in pathological intraocular pressure is more damaged in eyes without antiglaucoma treatment. Patients and Methods: The cohort consisted of 69 subjects (122 eyes), 32 males (6x one, 26x both eyes) aged 21 to 76 years and 37 females (4x one and 30x both eyes) aged 22 to 75 years, who were measured to have IOP greater than 21 mmHg (21– 36) in routine ambulatory care. Measurements were performed using the Ocular Response Analyser, taking into account corneal hysteresis. RNFL thickness was measured using the Avanti RTVue XR and was assessed in 8 segments (1-IT, 2-TI, 3-TS, 4-ST, 5-SN, 6-NS, 7-NI, 8-IN). The visual field was examined with a fast threshold glaucoma program using the Medmont M700. The overall defect (OD) was evaluated. Pearson’s correlation coefficient r was used to assess the dependence between the selected parameters. Results: The largest peripapillary changes in RNFL were observed in segments 1, 4, 5 and 8. It should be emphasized that segments 1 and 4 have been temporarily shifted. Segments 5 and 8 then corresponded to the upper (at no. 12) and lower (at no. 6) sectors. Conclusion: The most important result of this study is the finding that the greatest changes in the RNFL layer were observed in pathological IOP at segment 5 (r=- 0.3) and 8 (r=- 0.28), at the point where the fibres of the magnocellular retinal ganglion cells enter the retina.
Název v anglickém jazyce
The Relationship Between the Thickness of cpRNFL in Segments and Intraocular Pressure
Popis výsledku anglicky
Purpose: The aim of this study was to investigate whether the retinal nerve fibre layer (RNFL) in some segments of the optic nerve disc in pathological intraocular pressure is more damaged in eyes without antiglaucoma treatment. Patients and Methods: The cohort consisted of 69 subjects (122 eyes), 32 males (6x one, 26x both eyes) aged 21 to 76 years and 37 females (4x one and 30x both eyes) aged 22 to 75 years, who were measured to have IOP greater than 21 mmHg (21– 36) in routine ambulatory care. Measurements were performed using the Ocular Response Analyser, taking into account corneal hysteresis. RNFL thickness was measured using the Avanti RTVue XR and was assessed in 8 segments (1-IT, 2-TI, 3-TS, 4-ST, 5-SN, 6-NS, 7-NI, 8-IN). The visual field was examined with a fast threshold glaucoma program using the Medmont M700. The overall defect (OD) was evaluated. Pearson’s correlation coefficient r was used to assess the dependence between the selected parameters. Results: The largest peripapillary changes in RNFL were observed in segments 1, 4, 5 and 8. It should be emphasized that segments 1 and 4 have been temporarily shifted. Segments 5 and 8 then corresponded to the upper (at no. 12) and lower (at no. 6) sectors. Conclusion: The most important result of this study is the finding that the greatest changes in the RNFL layer were observed in pathological IOP at segment 5 (r=- 0.3) and 8 (r=- 0.28), at the point where the fibres of the magnocellular retinal ganglion cells enter the retina.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical Ophthalmology
ISSN
1177-5483
e-ISSN
1177-5483
Svazek periodika
2022
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
NZ - Nový Zéland
Počet stran výsledku
7
Strana od-do
3673-3679
Kód UT WoS článku
000884743800001
EID výsledku v databázi Scopus
2-s2.0-85141502849