Monitoring of Liver RF Ablation Using UWB Radar: A Numerical Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F23%3A00368836" target="_blank" >RIV/68407700:21460/23:00368836 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/PIERS59004.2023.10221383" target="_blank" >https://doi.org/10.1109/PIERS59004.2023.10221383</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PIERS59004.2023.10221383" target="_blank" >10.1109/PIERS59004.2023.10221383</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monitoring of Liver RF Ablation Using UWB Radar: A Numerical Study
Popis výsledku v původním jazyce
Thermal ablation is a well-known method used in interventional radiology to treat cancer. The main objective of this study was a numerical investigation of RF liver ablation monitoring with the UWB radar. The eight UWB bowtie antennas were uniformly distributed around the liver area. The antennas were excited by the Gaussian pulse with frequencies ranging from 1 to 6 GHz. The catheter model (with diameter of 2 mm) was placed into the tumor position within the liver. The three concentric ellipsoids-shaped ablation zones were placed around the catheter to simulate the real clinical situation From the recorded signals the clutter was subtracted and results were visualized using the 'Delay and Sum' algorithm. A total three different tumor positions were considered within our study. This numerical analysis demonstrates the potential of the method to continuously monitor the ablation process using UWB radar. The ablation zones of three tumor positions were successfully reconstructed with a mean spatial precision lower than 2 mm. The results suggest that the UWB radar monitoring is applicable for continuous RF ablation monitoring with accuracy that is sufficient for therapeutic purposes.
Název v anglickém jazyce
Monitoring of Liver RF Ablation Using UWB Radar: A Numerical Study
Popis výsledku anglicky
Thermal ablation is a well-known method used in interventional radiology to treat cancer. The main objective of this study was a numerical investigation of RF liver ablation monitoring with the UWB radar. The eight UWB bowtie antennas were uniformly distributed around the liver area. The antennas were excited by the Gaussian pulse with frequencies ranging from 1 to 6 GHz. The catheter model (with diameter of 2 mm) was placed into the tumor position within the liver. The three concentric ellipsoids-shaped ablation zones were placed around the catheter to simulate the real clinical situation From the recorded signals the clutter was subtracted and results were visualized using the 'Delay and Sum' algorithm. A total three different tumor positions were considered within our study. This numerical analysis demonstrates the potential of the method to continuously monitor the ablation process using UWB radar. The ablation zones of three tumor positions were successfully reconstructed with a mean spatial precision lower than 2 mm. The results suggest that the UWB radar monitoring is applicable for continuous RF ablation monitoring with accuracy that is sufficient for therapeutic purposes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedigs of PIERS 2023 in Prague
ISBN
—
ISSN
1559-9450
e-ISSN
1559-9450
Počet stran výsledku
12
Strana od-do
672-683
Název nakladatele
Electromagnetics Academy
Místo vydání
Cambridge
Místo konání akce
Praha
Datum konání akce
3. 7. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—