EFFECT OF ELECTRODE BELT USED FOR LUNG MONITORING WITH ELECTRICAL IMPEDANCE TOMOGRAPHY ON TIDAL VOLUME IN HEALTHY SUBJECTS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F24%3A00378535" target="_blank" >RIV/68407700:21460/24:00378535 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.14311/CTJ.2024.3.01" target="_blank" >https://doi.org/10.14311/CTJ.2024.3.01</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CTJ.2024.3.01" target="_blank" >10.14311/CTJ.2024.3.01</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EFFECT OF ELECTRODE BELT USED FOR LUNG MONITORING WITH ELECTRICAL IMPEDANCE TOMOGRAPHY ON TIDAL VOLUME IN HEALTHY SUBJECTS
Popis výsledku v původním jazyce
Electrical impedance tomography is a radiation free, non-invasive lung monitoring method that is increasingly coming to the forefront of the interest of researchers and clinicians. The most frequently used EIT system PulmoVista 500 (Dräger Medical, Germany) uses stiff silicone electrode belt that is applied around the patient’s thorax to monitor the distribution of ventilation. To achieve proper electrode-skin connection and obtain high-quality signal, the electrode belt needs to be placed tightly at the level of 4th to 6th intercostal space. There is a possibility that tightly placed belt affects the compliance of the chest wall, tidal volume, and respiratory effort of the patient. In this study, we monitored tidal volumes using spirometer in 10 healthy, spontaneously breathing volunteers with and without the electrode belt applied around the thorax. Potentially clinically significant, but not statistically significant changes occurred in 70% of the subjects during calm breathing and in 90% of the subjects during forced breathing. The study did not determine whether the use of the electrode belt increases or decreases the value of tidal volume. However, when monitoring lung ventilation with EIT system, the possible influence of the stiff electrode belt on chest wall compliance and tidal volumes should be considered.
Název v anglickém jazyce
EFFECT OF ELECTRODE BELT USED FOR LUNG MONITORING WITH ELECTRICAL IMPEDANCE TOMOGRAPHY ON TIDAL VOLUME IN HEALTHY SUBJECTS
Popis výsledku anglicky
Electrical impedance tomography is a radiation free, non-invasive lung monitoring method that is increasingly coming to the forefront of the interest of researchers and clinicians. The most frequently used EIT system PulmoVista 500 (Dräger Medical, Germany) uses stiff silicone electrode belt that is applied around the patient’s thorax to monitor the distribution of ventilation. To achieve proper electrode-skin connection and obtain high-quality signal, the electrode belt needs to be placed tightly at the level of 4th to 6th intercostal space. There is a possibility that tightly placed belt affects the compliance of the chest wall, tidal volume, and respiratory effort of the patient. In this study, we monitored tidal volumes using spirometer in 10 healthy, spontaneously breathing volunteers with and without the electrode belt applied around the thorax. Potentially clinically significant, but not statistically significant changes occurred in 70% of the subjects during calm breathing and in 90% of the subjects during forced breathing. The study did not determine whether the use of the electrode belt increases or decreases the value of tidal volume. However, when monitoring lung ventilation with EIT system, the possible influence of the stiff electrode belt on chest wall compliance and tidal volumes should be considered.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika – Clinician and Technology
ISSN
0301-5491
e-ISSN
2336-5552
Svazek periodika
54
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
77-81
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85212774262