The Effect of Electrode Belt Size Selection upon Evaluation of the Distribution of Ventilation Using Electrical Impedance Tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F15%3A00235156" target="_blank" >RIV/68407700:21460/15:00235156 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7391453" target="_blank" >http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7391453</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effect of Electrode Belt Size Selection upon Evaluation of the Distribution of Ventilation Using Electrical Impedance Tomography
Popis výsledku v původním jazyce
Electrical impedance tomography (EIT) is a noninvasive diagnostic method enabling imaging of planar distribution of thorax impedance. Since EIT is not a routine tool in clinical practice, the examination methods have not been standardized yet. EIT systemPulmoVista 500 (Dräger Medical, Germany) uses an electrode belt with 16 equally distributed electrodes and with several options for its fastening around the thorax. The manufacturer produces five sizes of the belts that partly overlap. There are severalgroups of patients that can use both a smaller and bigger belt. The aim of this study is to investigate whether there is a significant difference in evaluation of regional ventilation using EIT in case of using two sizes of electrode belt in the same subject and therefore the even distribution of electrodes is not maintained. Thirty healthy subjects were measured in horizontal and vertical position with two belt sizes separately. Significant differences in distribution of ventilation wh
Název v anglickém jazyce
The Effect of Electrode Belt Size Selection upon Evaluation of the Distribution of Ventilation Using Electrical Impedance Tomography
Popis výsledku anglicky
Electrical impedance tomography (EIT) is a noninvasive diagnostic method enabling imaging of planar distribution of thorax impedance. Since EIT is not a routine tool in clinical practice, the examination methods have not been standardized yet. EIT systemPulmoVista 500 (Dräger Medical, Germany) uses an electrode belt with 16 equally distributed electrodes and with several options for its fastening around the thorax. The manufacturer produces five sizes of the belts that partly overlap. There are severalgroups of patients that can use both a smaller and bigger belt. The aim of this study is to investigate whether there is a significant difference in evaluation of regional ventilation using EIT in case of using two sizes of electrode belt in the same subject and therefore the even distribution of electrodes is not maintained. Thirty healthy subjects were measured in horizontal and vertical position with two belt sizes separately. Significant differences in distribution of ventilation wh
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20102015062" target="_blank" >VG20102015062: Výzkumná podpora HZS ČR a dalších složek IZS ČR</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The 5th IEEE International Conference on E-Health and Bioengineering
ISBN
978-1-4673-7545-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Gr. T. Popa University of Medicine and Pharmacy
Místo vydání
Iasi
Místo konání akce
Iasi
Datum konání akce
19. 11. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—