Response Analysis of a Building Loaded by Technical Seismicity Propagating from a Tube Reiway Structure
Popis výsledku v původním jazyce
This paper deals with the response analysis of a rubber vibro-base insulated building structure, based on a foundation pile structure. An elastic rubber course separates the upper and lower parts of the foundation plate and the footings. The structure isloaded by groundborne vibrations from an underground railway system. The actual history of the dynamic load measured on the pile heads was used as input data for the design of the vibro-base insulation and for a dynamic analysis of the structure. The whole bearing structure, subdivided into floor plates, columns, walls and girders, was taken into account in the structure calculation model. The rubber bed was modelled as Winkler-Pasternak supports in the part of the foundation plate and the elastic supports of the collumns and walls. The floor vibrations are predicted and compared with the non-insulated state of the building.
Název v anglickém jazyce
Response Analysis of a Building Loaded by Technical Seismicity Propagating from a Tube Reiway Structure
Popis výsledku anglicky
This paper deals with the response analysis of a rubber vibro-base insulated building structure, based on a foundation pile structure. An elastic rubber course separates the upper and lower parts of the foundation plate and the footings. The structure isloaded by groundborne vibrations from an underground railway system. The actual history of the dynamic load measured on the pile heads was used as input data for the design of the vibro-base insulation and for a dynamic analysis of the structure. The whole bearing structure, subdivided into floor plates, columns, walls and girders, was taken into account in the structure calculation model. The rubber bed was modelled as Winkler-Pasternak supports in the part of the foundation plate and the elastic supports of the collumns and walls. The floor vibrations are predicted and compared with the non-insulated state of the building.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F03%2F0082" target="_blank" >GA103/03/0082: Nelineární odezva konstrukcí při mimořádných zatíženích a zatíženích způsobených pohybem člověka</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Earthquake Resistant Engineering Structures V
ISBN
1-84564-018-7
Počet stran výsledku
10
Strana od-do
675-684
Počet stran knihy
—
Název nakladatele
WIT PRESS
Místo vydání
Wessex