The Use of Rubber Vibro-base Isolation to Decrease Structure Dynamic Response
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F12%3A00201412" target="_blank" >RIV/68407700:21610/12:00201412 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Use of Rubber Vibro-base Isolation to Decrease Structure Dynamic Response
Popis výsledku v původním jazyce
The use of rubber or another elastomer in the foundation structure is an efficient solution to reduce vibrations propagating into the building structure through the subsoil. The principle of vibro-base isolation consists in inserting an elastic layer between the dual foundation plates, with protective hydroisolation against water flooding. The example of reinforced concrete structure of the building is used to show the efficiency of vibro-base isolation, comparing isolated versus non-isolated structures. This efficiency is assessed based on computational prognosis of vibration of the building floors. Non-stationary dynamic load by the measured vibrations due to technical seismicity caused by underground cars passing near the analyzed structure is usedto calculate the building response.
Název v anglickém jazyce
The Use of Rubber Vibro-base Isolation to Decrease Structure Dynamic Response
Popis výsledku anglicky
The use of rubber or another elastomer in the foundation structure is an efficient solution to reduce vibrations propagating into the building structure through the subsoil. The principle of vibro-base isolation consists in inserting an elastic layer between the dual foundation plates, with protective hydroisolation against water flooding. The example of reinforced concrete structure of the building is used to show the efficiency of vibro-base isolation, comparing isolated versus non-isolated structures. This efficiency is assessed based on computational prognosis of vibration of the building floors. Non-stationary dynamic load by the measured vibrations due to technical seismicity caused by underground cars passing near the analyzed structure is usedto calculate the building response.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JM - Inženýrské stavitelství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F11%2F1580" target="_blank" >GAP105/11/1580: Přechodová odezva konstrukcí při krátkodobém dynamickém nebo rázovém zatížení od seismických účinků a výbuchů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2012
ISBN
978-80-86246-40-6
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
849-855
Název nakladatele
Institute of Theoretical and Applied Mechanics Academy of Sciences of the Czech Republic
Místo vydání
Prague
Místo konání akce
Svratka
Datum konání akce
14. 5. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—