Study of Corrosion Damage of Glass Fibers in Textile Fiberglass Reinforcement under Expositions Simulating Concrete Environment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F18%3A00325473" target="_blank" >RIV/68407700:21610/18:00325473 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.272.189" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/SSP.272.189</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.272.189" target="_blank" >10.4028/www.scientific.net/SSP.272.189</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of Corrosion Damage of Glass Fibers in Textile Fiberglass Reinforcement under Expositions Simulating Concrete Environment
Popis výsledku v původním jazyce
The main point of this paper is to assess the level of corrosion damage of the composite textile fiberglass reinforcement in environments that simulate the concrete pore solution by the techniques of FT-IR (Fourier transform infrared spectroscopy), SEM (scanning electron microscopy) as well as EDS (scanning electron microscopy). Effect of corrosion on the tensile strength segmented textile glass fiber was tested and also it was investigated specific type of protective organic coating on glass fiber. The results express the evidence of local corrosion damage on the examined samples just at pH 13.5, and on the contrary high stability in the environment simulating carbonated concrete and concrete contaminated by chloride anions. The thesis also points on the unevenness of the excluded protective organic coating with localized porosity which relates to the above mentioned corrosion damage.
Název v anglickém jazyce
Study of Corrosion Damage of Glass Fibers in Textile Fiberglass Reinforcement under Expositions Simulating Concrete Environment
Popis výsledku anglicky
The main point of this paper is to assess the level of corrosion damage of the composite textile fiberglass reinforcement in environments that simulate the concrete pore solution by the techniques of FT-IR (Fourier transform infrared spectroscopy), SEM (scanning electron microscopy) as well as EDS (scanning electron microscopy). Effect of corrosion on the tensile strength segmented textile glass fiber was tested and also it was investigated specific type of protective organic coating on glass fiber. The results express the evidence of local corrosion damage on the examined samples just at pH 13.5, and on the contrary high stability in the environment simulating carbonated concrete and concrete contaminated by chloride anions. The thesis also points on the unevenness of the excluded protective organic coating with localized porosity which relates to the above mentioned corrosion damage.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
24th Concrete Days 2017
ISBN
978-3-0357-1284-1
ISSN
1012-0394
e-ISSN
1662-9779
Počet stran výsledku
8
Strana od-do
189-196
Název nakladatele
Trans Tech Publications
Místo vydání
Curich
Místo konání akce
Litomyšl
Datum konání akce
22. 11. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—