The paper deals with analysis and comparison of long-term measurements of CO2 concentration in two different bedrooms. The bedrooms were regularly occupied by persons. Bedrooms are different in size, number of people, type of windows and also exterior wall. However, these two real microclimates can be specified simplified into comparable models. In the first case it is a naturally ventilated room, without thermal insulation of the exterior wall with the original double lining windows and in the second case it is a space with an insulated exterior wall and plastic windows with triple glazing. The aim is to compare the CO2 concentration in the microclimate with the original window and with the modern single-glazed window with triple glazing after reconstruction.
Název v anglickém jazyce
Comparison of CO2 concentration in a room with refurbished windows and in a room with original windows
Popis výsledku anglicky
The paper deals with analysis and comparison of long-term measurements of CO2 concentration in two different bedrooms. The bedrooms were regularly occupied by persons. Bedrooms are different in size, number of people, type of windows and also exterior wall. However, these two real microclimates can be specified simplified into comparable models. In the first case it is a naturally ventilated room, without thermal insulation of the exterior wall with the original double lining windows and in the second case it is a space with an insulated exterior wall and plastic windows with triple glazing. The aim is to compare the CO2 concentration in the microclimate with the original window and with the modern single-glazed window with triple glazing after reconstruction.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20102 - Construction engineering, Municipal and structural engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sanace a rekonstrukce staveb 2019
ISBN
978-80-02-02888-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
47-52
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
28. 11. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—