Sledování sběru náboje v křemíkových pixelových detektorech pomocí stop protoný a alfa částic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F07%3A15142699" target="_blank" >RIV/68407700:21670/07:15142699 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Charge collection from proton and alpha particle tracks in silicon pixel detector devices
Popis výsledku v původním jazyce
The lateral spread of charge carriers under the influence of the electric field in a pixellated silicon detector hit by a heavy charged particle, such as a proton or an alpha-particle, causes a sharing of the charge between the electrodes and many pixelshave a signal. The results of the charge sharing effect measured in the Medipix2 and Timepix pixel detectors of 300 um thicknesses is shown as a function of particle energy and applied bias voltage. A model describing the effects of funneling, plasma and diffusion on the charge collection and its sharing will be also presented. Using Timepix, it is possible to measure directly the quantity of charge deposited in each pixel within the cluster and to follow changes in charge collection as a function of collection time. This allows 3D-visualization of individual tracks of charged particles in silicon with Timepix.
Název v anglickém jazyce
Charge collection from proton and alpha particle tracks in silicon pixel detector devices
Popis výsledku anglicky
The lateral spread of charge carriers under the influence of the electric field in a pixellated silicon detector hit by a heavy charged particle, such as a proton or an alpha-particle, causes a sharing of the charge between the electrodes and many pixelshave a signal. The results of the charge sharing effect measured in the Medipix2 and Timepix pixel detectors of 300 um thicknesses is shown as a function of particle energy and applied bias voltage. A model describing the effects of funneling, plasma and diffusion on the charge collection and its sharing will be also presented. Using Timepix, it is possible to measure directly the quantity of charge deposited in each pixel within the cluster and to follow changes in charge collection as a function of collection time. This allows 3D-visualization of individual tracks of charged particles in silicon with Timepix.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2007 IEEE Nuclear Science Symposium & Medical Imaging Conference
ISBN
—
ISSN
1082-3654
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Omipress
Místo vydání
Wisconsin
Místo konání akce
Hawai
Datum konání akce
27. 10. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—