Analýza materiálu pomocí transmisních rentgenových spekter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F08%3A10151981" target="_blank" >RIV/68407700:21670/08:10151981 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Material Analysis Using Characteristic Transmission Spectra
Popis výsledku v původním jazyce
Measuring the X-ray photon flux together with evaluation of the transmittion spectra can solve this problem. The well known Dual-energy X-ray technique works with two radiograms, differing by distinct X-ray source spectra, acquired from the same point ofview. Thus, both density and material composition can be resolved by this way. Since the TimePix pixel single photon counting detector is energy sensitive, we can use it for measuring the energy spectra of the X-ray beam transmitted through the inspected sample. This can be done in each detector pixel by measuring the energy of single X ray photons. The event-by-event measurement has to be performed with low X ray photon flux to avoid overlapping of individual events in individual pixels. It will be shown that higher accuracy can be reached by this method in comparison with the integrating Dual Energy Method.
Název v anglickém jazyce
Material Analysis Using Characteristic Transmission Spectra
Popis výsledku anglicky
Measuring the X-ray photon flux together with evaluation of the transmittion spectra can solve this problem. The well known Dual-energy X-ray technique works with two radiograms, differing by distinct X-ray source spectra, acquired from the same point ofview. Thus, both density and material composition can be resolved by this way. Since the TimePix pixel single photon counting detector is energy sensitive, we can use it for measuring the energy spectra of the X-ray beam transmitted through the inspected sample. This can be done in each detector pixel by measuring the energy of single X ray photons. The event-by-event measurement has to be performed with low X ray photon flux to avoid overlapping of individual events in individual pixels. It will be shown that higher accuracy can be reached by this method in comparison with the integrating Dual Energy Method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06041" target="_blank" >LC06041: Příprava, modifikace a charakterizace materiálů energetickým zářením</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Conference Record of the 2008 IEEE NSS/MIC/RTSD
ISBN
978-1-4244-2715-4
ISSN
1082-3654
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Omipress
Místo vydání
Wisconsin
Místo konání akce
Dresden
Datum konání akce
19. 10. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—