Zvyšování prostorového rozlišení rentgenografických metod pomocí dekonvoluce
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F08%3A15152326" target="_blank" >RIV/68407700:21670/08:15152326 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution
Popis výsledku v původním jazyce
The spatial resolution of X-ray micro radiography is the crucial parameter. Its improvement remains a major experimental and data processing challenge. The lower limit of the spatial resolution of a radiographic method is given by the size of the point spread function (PSF). In the case of high geometrical magnification, the X-ray spot size becomes the most important factor for PSF determination. We have successfully measured in 2-D the X-ray spot shape and using deconvolution the spatial resolution hasbeen improved up to three-fold. We have successfully illustrated the approach for real biological and material structure investigations. Another possibility for resolution enhancement is sub-pixel micro-shifting of the X-ray detector. Although this approach is quite common for optical imaging, it has not been fully investigated for X-ray imaging. In our measurements we have used sub-pixel micro-shifts of the Medipix2 detector. The method is successfully presented on real objects.
Název v anglickém jazyce
Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution
Popis výsledku anglicky
The spatial resolution of X-ray micro radiography is the crucial parameter. Its improvement remains a major experimental and data processing challenge. The lower limit of the spatial resolution of a radiographic method is given by the size of the point spread function (PSF). In the case of high geometrical magnification, the X-ray spot size becomes the most important factor for PSF determination. We have successfully measured in 2-D the X-ray spot shape and using deconvolution the spatial resolution hasbeen improved up to three-fold. We have successfully illustrated the approach for real biological and material structure investigations. Another possibility for resolution enhancement is sub-pixel micro-shifting of the X-ray detector. Although this approach is quite common for optical imaging, it has not been fully investigated for X-ray imaging. In our measurements we have used sub-pixel micro-shifts of the Medipix2 detector. The method is successfully presented on real objects.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06041" target="_blank" >LC06041: Příprava, modifikace a charakterizace materiálů energetickým zářením</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Conference Record of the 2008 IEEE NSS/MIC/RTSD
ISBN
978-1-4244-2715-4
ISSN
1082-3654
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Omipress
Místo vydání
Wisconsin
Místo konání akce
Dresden
Datum konání akce
19. 10. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—