Projekt RELAXd: vývoj čtyřstranně rozšiřitelných zobrazovačů jednotlivých fotonů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F08%3A15152341" target="_blank" >RIV/68407700:21670/08:15152341 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The RELAXd project: development of four-side tilable photon counting imagers
Popis výsledku v původním jazyce
The feasibility of using photon-counting imaging techniques with X-rays, neutrons or other types of radiation for many applications in materials analysis and bio-medical sciences, has already been well demonstrated. A hybrid imager consisting of an appropriate sensor chip flip-chipped on top of a Medipix2 readout ASIC is an example of such a device. It can count single X-ray photons, without any noise or dark current, at high fluxes (several Gigaphotons per cm2 per second). The limiting factors for morewidespread usage of these devices in bio-medical applications are the small size of the active area (about 2 cm2 per chip) and the low frame rate. The aim of the RELAXd project (high REsolution Large Area X-ray Detector) is to develop a high frame-rate,fully 3D-integrated microsystem, consisting of four Medipix2 readout chips bump-bonded to one silicon sensor chip. This paper presents first results of this task focusing on the necesary wafer-level post processing technologies.
Název v anglickém jazyce
The RELAXd project: development of four-side tilable photon counting imagers
Popis výsledku anglicky
The feasibility of using photon-counting imaging techniques with X-rays, neutrons or other types of radiation for many applications in materials analysis and bio-medical sciences, has already been well demonstrated. A hybrid imager consisting of an appropriate sensor chip flip-chipped on top of a Medipix2 readout ASIC is an example of such a device. It can count single X-ray photons, without any noise or dark current, at high fluxes (several Gigaphotons per cm2 per second). The limiting factors for morewidespread usage of these devices in bio-medical applications are the small size of the active area (about 2 cm2 per chip) and the low frame rate. The aim of the RELAXd project (high REsolution Large Area X-ray Detector) is to develop a high frame-rate,fully 3D-integrated microsystem, consisting of four Medipix2 readout chips bump-bonded to one silicon sensor chip. This paper presents first results of this task focusing on the necesary wafer-level post processing technologies.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06041" target="_blank" >LC06041: Příprava, modifikace a charakterizace materiálů energetickým zářením</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
2008
Číslo periodika v rámci svazku
591
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000257529300060
EID výsledku v databázi Scopus
—