Study of charge sharing in a silicon pixel detector with heavy ionizing particles interacting with a Medipix2 device
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F09%3A00165386" target="_blank" >RIV/68407700:21670/09:00165386 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of charge sharing in a silicon pixel detector with heavy ionizing particles interacting with a Medipix2 device
Popis výsledku v původním jazyce
The charge sharing effect among adjacent pixels of a Medipix2 pixel detector comes from the lateral spread of charges generated from the interaction of an ionizing particle in silicon. The charge sharing follows specific ionizing losses of particle alongits track in silicon influenced by several effects that cause the lateral spread of the charge such as the plasma effect, charge column erosion and funneling on top of diffusion and drift processes in an electric field. A model that takes into account these effects has been used to fit results of cluster size measurements as a function of the bias voltage for a Medipix2 silicon pixel detector (256 x 256 pixels, each measuring 55 mu m x 55 mu m x 300 mu m) exposed to a beam of heavily ionizing particles(protons, alpha-particles, carbon, and oxygen ions). Results on the response of the device to protons with different incident angles are also presented.
Název v anglickém jazyce
Study of charge sharing in a silicon pixel detector with heavy ionizing particles interacting with a Medipix2 device
Popis výsledku anglicky
The charge sharing effect among adjacent pixels of a Medipix2 pixel detector comes from the lateral spread of charges generated from the interaction of an ionizing particle in silicon. The charge sharing follows specific ionizing losses of particle alongits track in silicon influenced by several effects that cause the lateral spread of the charge such as the plasma effect, charge column erosion and funneling on top of diffusion and drift processes in an electric field. A model that takes into account these effects has been used to fit results of cluster size measurements as a function of the bias voltage for a Medipix2 silicon pixel detector (256 x 256 pixels, each measuring 55 mu m x 55 mu m x 300 mu m) exposed to a beam of heavily ionizing particles(protons, alpha-particles, carbon, and oxygen ions). Results on the response of the device to protons with different incident angles are also presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06041" target="_blank" >LC06041: Příprava, modifikace a charakterizace materiálů energetickým zářením</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
607
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
000268987900056
EID výsledku v databázi Scopus
—