Study of the charge sharing in silicon pixel detector by means of heavy ionizing particles interacting with a Medipix2 device
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F11%3A00191665" target="_blank" >RIV/68407700:21670/11:00191665 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2010.06.141" target="_blank" >http://dx.doi.org/10.1016/j.nima.2010.06.141</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2010.06.141" target="_blank" >10.1016/j.nima.2010.06.141</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of the charge sharing in silicon pixel detector by means of heavy ionizing particles interacting with a Medipix2 device
Popis výsledku v původním jazyce
The charge sharing effect has been investigated in a 300 mu m thick silicon pixel detector bump-bonded to a Medipix2 readout chip and exposed to heavy ionizing particles of various energies, namely protons and alpha-particles. The lateral spread of the charge carriers from the interaction of a heavy ionizing particle in the silicon detector causes a sharing of the charge among adjacent pixels, giving a signal in clusters of multiple pixels of the Medipix2 device. A model of charge sharing, including theplasma effect on top of diffusion and drift processes has been compared to the measured lateral spread of the charge for bias voltage values beyond the full depletion voltage. Results of the measurements of the cluster size as a function of the energy and incidence angle of incoming heavy ionizing particles are also reported and compared with the model.
Název v anglickém jazyce
Study of the charge sharing in silicon pixel detector by means of heavy ionizing particles interacting with a Medipix2 device
Popis výsledku anglicky
The charge sharing effect has been investigated in a 300 mu m thick silicon pixel detector bump-bonded to a Medipix2 readout chip and exposed to heavy ionizing particles of various energies, namely protons and alpha-particles. The lateral spread of the charge carriers from the interaction of a heavy ionizing particle in the silicon detector causes a sharing of the charge among adjacent pixels, giving a signal in clusters of multiple pixels of the Medipix2 device. A model of charge sharing, including theplasma effect on top of diffusion and drift processes has been compared to the measured lateral spread of the charge for bias voltage values beyond the full depletion voltage. Results of the measurements of the cluster size as a function of the energy and incidence angle of incoming heavy ionizing particles are also reported and compared with the model.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
633
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
117-120
Kód UT WoS článku
000292782400036
EID výsledku v databázi Scopus
—