Micro-Probe for Medical Radiation Imaging Based on Medipix2 Detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F10%3A00179967" target="_blank" >RIV/68407700:21670/10:00179967 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Micro-Probe for Medical Radiation Imaging Based on Medipix2 Detector
Popis výsledku v původním jazyce
For medical imaging applications the emphasis is generally put on obtaining high resolution and low dose images of samples or patients. All this features can be covered by using the single photon counting devices like Medipix and advanced techniques of image reconstruction. In case that intra-operative approach is advantageous, like in direct observation of dental implants, also the size of the imaging device itself plays critical role. Therefore we manufactured the miniaturized version of currently used USB interface accommodating also the Medipix2 chip itself on the same printed circuit board. The dimensions of the whole imaging device are reduced to 15 mm x 60 mm (which means that 25% out of the total device size is actually sensitive area). Detector of this size can easily fit directly into the patients' mount.
Název v anglickém jazyce
Micro-Probe for Medical Radiation Imaging Based on Medipix2 Detector
Popis výsledku anglicky
For medical imaging applications the emphasis is generally put on obtaining high resolution and low dose images of samples or patients. All this features can be covered by using the single photon counting devices like Medipix and advanced techniques of image reconstruction. In case that intra-operative approach is advantageous, like in direct observation of dental implants, also the size of the imaging device itself plays critical role. Therefore we manufactured the miniaturized version of currently used USB interface accommodating also the Medipix2 chip itself on the same printed circuit board. The dimensions of the whole imaging device are reduced to 15 mm x 60 mm (which means that 25% out of the total device size is actually sensitive area). Detector of this size can easily fit directly into the patients' mount.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2009 IEEE Nuclear Science Symposium Conference Record
ISBN
978-1-4244-3961-4
ISSN
1082-3654
e-ISSN
—
Počet stran výsledku
3
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Orlando (Florida)
Datum konání akce
25. 10. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000280505101244