Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging

Identifikátory výsledku

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging

  • Popis výsledku v původním jazyce

    X-ray phase contrast imaging using a single absorption grating and a hybrid semiconductor pixel detector is a newly introduced approach with great potential for application in medicine, biology and material research. In comparison with a conventional grating interferometer technique, which requires a multiple-exposure (phase-stepping) procedure, our method is greatly simplified, because both phase gradient and absorption images are obtained from just one exposure. Consequently, the approach can significantly reduce the time-consuming scanning and also possibly the dose. Examples of application of the approach as an imaging tool for investigations in biology are presented. Particularly, we present the extension of our 1-D single grating method to a two-direction sensitive technique. In a single exposure, phase gradient images in two perpendicular directions together with the conventional attenuation image are produced. Results of the proof-of-concept experiment are presented.

  • Název v anglickém jazyce

    Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging

  • Popis výsledku anglicky

    X-ray phase contrast imaging using a single absorption grating and a hybrid semiconductor pixel detector is a newly introduced approach with great potential for application in medicine, biology and material research. In comparison with a conventional grating interferometer technique, which requires a multiple-exposure (phase-stepping) procedure, our method is greatly simplified, because both phase gradient and absorption images are obtained from just one exposure. Consequently, the approach can significantly reduce the time-consuming scanning and also possibly the dose. Examples of application of the approach as an imaging tool for investigations in biology are presented. Particularly, we present the extension of our 1-D single grating method to a two-direction sensitive technique. In a single exposure, phase gradient images in two perpendicular directions together with the conventional attenuation image are produced. Results of the proof-of-concept experiment are presented.

Klasifikace

  • Druh

    Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)

  • CEP obor

    BG - Jaderná, atomová a molekulová fyzika, urychlovače

  • OECD FORD obor

Návaznosti výsledku

Ostatní

  • Rok uplatnění

    2011

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

  • Svazek periodika

    6

  • Číslo periodika v rámci svazku

  • Stát vydavatele periodika

    IT - Italská republika

  • Počet stran výsledku

    10

  • Strana od-do

    1-10

  • Kód UT WoS článku

    000291345600078

  • EID výsledku v databázi Scopus

Základní informace

Druh výsledku

Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)

Jx

CEP

BG - Jaderná, atomová a molekulová fyzika, urychlovače

Rok uplatnění

2011