Single absorption grating based X-ray phase contrast CT using Timepix detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F19%3A00337174" target="_blank" >RIV/68407700:21670/19:00337174 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1748-0221/14/05/C05007" target="_blank" >https://doi.org/10.1088/1748-0221/14/05/C05007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/14/05/C05007" target="_blank" >10.1088/1748-0221/14/05/C05007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Single absorption grating based X-ray phase contrast CT using Timepix detector
Popis výsledku v původním jazyce
Single absorption grating based X-ray phase contrast imaging (XPCI) with a hybrid pixel detector Timepix is a promising technique in many application fields (material sciences, biology, medicine etc.). Conventional coded aperture approach with microfocus source uses two absorption gratings where one of them is moved in steps (so-called phase stepping). In contrast to that, the proposed XPCI approach provides the absorption, phase contrast and dark field images from a single acquisition. This leads to higher mechanical stability of the system and decrease of the delivered dose. Moreover, faster data acquisition increases the usability of the system for CT measurements and dynamic phase radiography.
Název v anglickém jazyce
Single absorption grating based X-ray phase contrast CT using Timepix detector
Popis výsledku anglicky
Single absorption grating based X-ray phase contrast imaging (XPCI) with a hybrid pixel detector Timepix is a promising technique in many application fields (material sciences, biology, medicine etc.). Conventional coded aperture approach with microfocus source uses two absorption gratings where one of them is moved in steps (so-called phase stepping). In contrast to that, the proposed XPCI approach provides the absorption, phase contrast and dark field images from a single acquisition. This leads to higher mechanical stability of the system and decrease of the delivered dose. Moreover, faster data acquisition increases the usability of the system for CT measurements and dynamic phase radiography.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000766" target="_blank" >EF16_019/0000766: Inženýrské aplikace fyziky mikrosvěta</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Svazek periodika
14
Číslo periodika v rámci svazku
C05007
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000468725500002
EID výsledku v databázi Scopus
2-s2.0-85069578121