BrachyView: Tomographic Reconstruction Using Timepix Detectors In Post-Implant Dosimetry Checks For Permanent Prostate Brachytherapy Implants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F13%3A00310002" target="_blank" >RIV/68407700:21670/13:00310002 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6829455" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6829455</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/NSSMIC.2013.6829854" target="_blank" >10.1109/NSSMIC.2013.6829854</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
BrachyView: Tomographic Reconstruction Using Timepix Detectors In Post-Implant Dosimetry Checks For Permanent Prostate Brachytherapy Implants
Popis výsledku v původním jazyce
Computed tomography imaging is a mandatory part of the permanent prostate brachytherapy procedure. It is used as a post-implant dosimetric check to evaluate the quality of the implant. It is proposed that by using a novel assembly of multiple high-resolution pixelated detectors Timepix, an in-body probe can be used as a multi-modality imaging device. Preliminary phantom studies of a PMMA prostate phantom with implanted dummy I-125 seeds (Oncura Model 6711) have shown a qualitative confirmation of three-dimensional tomographic reconstruction from limited angles and limited field of view based on iterative reconstruction algorithms.
Název v anglickém jazyce
BrachyView: Tomographic Reconstruction Using Timepix Detectors In Post-Implant Dosimetry Checks For Permanent Prostate Brachytherapy Implants
Popis výsledku anglicky
Computed tomography imaging is a mandatory part of the permanent prostate brachytherapy procedure. It is used as a post-implant dosimetric check to evaluate the quality of the implant. It is proposed that by using a novel assembly of multiple high-resolution pixelated detectors Timepix, an in-body probe can be used as a multi-modality imaging device. Preliminary phantom studies of a PMMA prostate phantom with implanted dummy I-125 seeds (Oncura Model 6711) have shown a qualitative confirmation of three-dimensional tomographic reconstruction from limited angles and limited field of view based on iterative reconstruction algorithms.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)
ISBN
978-1-4799-0534-8
ISSN
1082-3654
e-ISSN
—
Počet stran výsledku
3
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Seoul
Datum konání akce
27. 10. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000347163502034