MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for an experimental tomograph Bruker 47/20
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F14%3A00224292" target="_blank" >RIV/68407700:21670/14:00224292 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.utef.cvut.cz/cz/index.php?Ns=103&id=1000088" target="_blank" >http://www.utef.cvut.cz/cz/index.php?Ns=103&id=1000088</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for an experimental tomograph Bruker 47/20
Popis výsledku v původním jazyce
This work presents MRI-SPECT insert system designed for a combination of anatomical (MRI) and functional (SPECT) imaging (Multimodal Imaging) in experimental tomograph Bruker with magnetic induction of 4.7 Tesla. Insert system includes SPECT setup with CdTe detectors, MRI compatible tungsten collimators and radiofrequency (RF) coil placed in the middle of the whole system. To the RF coil is inserted measuring object - currently the high proton-density (PD) phantom (1H) with embedded radioisotopic gammasource (57Co), in the future it will be a mouse. Reading of SPECT is ensured by 1.5 m cables conducted outside the tomograph to the readout electronics (FitPix USB 1.0) due to the suppression of the effects of high magnetic field on the functionality ofboth methods. Fused image (MRI+SPECT) is possible to get by consecutive measurements of MRI and SPECT.
Název v anglickém jazyce
MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for an experimental tomograph Bruker 47/20
Popis výsledku anglicky
This work presents MRI-SPECT insert system designed for a combination of anatomical (MRI) and functional (SPECT) imaging (Multimodal Imaging) in experimental tomograph Bruker with magnetic induction of 4.7 Tesla. Insert system includes SPECT setup with CdTe detectors, MRI compatible tungsten collimators and radiofrequency (RF) coil placed in the middle of the whole system. To the RF coil is inserted measuring object - currently the high proton-density (PD) phantom (1H) with embedded radioisotopic gammasource (57Co), in the future it will be a mouse. Reading of SPECT is ensured by 1.5 m cables conducted outside the tomograph to the readout electronics (FitPix USB 1.0) due to the suppression of the effects of high magnetic field on the functionality ofboth methods. Fused image (MRI+SPECT) is possible to get by consecutive measurements of MRI and SPECT.
Klasifikace
Druh
G<sub>funk</sub> - Funkční vzorek
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
MRI-SPECT insert system
Číselná identifikace
—
Technické parametry
průměr = 9,2 cm; pro 5 CdTe detektorů
Ekonomické parametry
10000 (2x CdTe detector) + 3000 eur
Kategorie aplik. výsledku dle nákladů
—
IČO vlastníka výsledku
68407700
Název vlastníka
ČVUT ÚTEF
Stát vlastníka
CZ - Česká republika
Druh možnosti využití
P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence
Požadavek na licenční poplatek
Z - Poskytovatel licence na výsledek nepožaduje v některých případech licenční poplatek
Adresa www stránky s výsledkem
—