BrachyView: multiple seed position reconstruction and comparison with CT post-implant dosimetry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F16%3A00349483" target="_blank" >RIV/68407700:21670/16:00349483 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1748-0221/11/05/P05002" target="_blank" >https://doi.org/10.1088/1748-0221/11/05/P05002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/11/05/P05002" target="_blank" >10.1088/1748-0221/11/05/P05002</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
BrachyView: multiple seed position reconstruction and comparison with CT post-implant dosimetry
Popis výsledku v původním jazyce
BrachyView is a novel in-body imaging system utilising high-resolution pixelated silicon detectors (Timepix) and a pinhole collimator for brachytherapy source localisation. Recent studies have investigated various options for real-time intraoperative dynamic dose treatment planning to increase the quality of implants. In a previous proof-of-concept study, the justification of the pinhole concept was shown, allowing for the next step whereby multiple active seeds are implanted into a PMMA phantom to simulate a more realistic clinical scenario. In this study, 20 seeds were implanted and imaged using a lead pinhole of 400 μ m diameter. BrachyView was able to resolve the seed positions within 1–2 mm of expected positions, which was verified by co-registering with a full clinical post-implant CT scan.
Název v anglickém jazyce
BrachyView: multiple seed position reconstruction and comparison with CT post-implant dosimetry
Popis výsledku anglicky
BrachyView is a novel in-body imaging system utilising high-resolution pixelated silicon detectors (Timepix) and a pinhole collimator for brachytherapy source localisation. Recent studies have investigated various options for real-time intraoperative dynamic dose treatment planning to increase the quality of implants. In a previous proof-of-concept study, the justification of the pinhole concept was shown, allowing for the next step whereby multiple active seeds are implanted into a PMMA phantom to simulate a more realistic clinical scenario. In this study, 20 seeds were implanted and imaged using a lead pinhole of 400 μ m diameter. BrachyView was able to resolve the seed positions within 1–2 mm of expected positions, which was verified by co-registering with a full clinical post-implant CT scan.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30500 - Other medical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Svazek periodika
11
Číslo periodika v rámci svazku
05
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000377851700025
EID výsledku v databázi Scopus
2-s2.0-84969234024