PV and Heat Pump System with a Seasonal Storage for NZEB House
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F17%3A00316377" target="_blank" >RIV/68407700:21720/17:00316377 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
PV and Heat Pump System with a Seasonal Storage for NZEB House
Popis výsledku v původním jazyce
Energy system consisting of combined ground-air source heat pump, PV system and seasonal ground storage for energy passive family house has been developed and analysed by computer simulation. The heat pump is equipped with a desuperheater to prepare hot water and variable speed compressor to adapt power to PV system production. Heat pump during summer operation transforms the ambient heat to charge the ground seasonal storage with use of the PV electricity only. Winter operation relies on the heat stored under the house and low grid electricity consumption. The simulation analysis have shown the significant decrease of the grid electricity needs for the house (system SPF increased from 2.9 for reference borehole system to 4.7) and increase in usability of local PV electricity production for energy supply (space heating, hot water) in the house. In total, 80 % of energy supply for the house is renewable energy and specific non-renewable primary energy need of the house is 22 kWh/m2.a (for space heating, hot water and auxiliary energy).
Název v anglickém jazyce
PV and Heat Pump System with a Seasonal Storage for NZEB House
Popis výsledku anglicky
Energy system consisting of combined ground-air source heat pump, PV system and seasonal ground storage for energy passive family house has been developed and analysed by computer simulation. The heat pump is equipped with a desuperheater to prepare hot water and variable speed compressor to adapt power to PV system production. Heat pump during summer operation transforms the ambient heat to charge the ground seasonal storage with use of the PV electricity only. Winter operation relies on the heat stored under the house and low grid electricity consumption. The simulation analysis have shown the significant decrease of the grid electricity needs for the house (system SPF increased from 2.9 for reference borehole system to 4.7) and increase in usability of local PV electricity production for energy supply (space heating, hot water) in the house. In total, 80 % of energy supply for the house is renewable energy and specific non-renewable primary energy need of the house is 22 kWh/m2.a (for space heating, hot water and auxiliary energy).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 12th IEA Heat Pump Conference
ISBN
978-90-90-30412-0
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
The IEA Heat Pump Programme
Místo vydání
Montreal, Quebec
Místo konání akce
Rotterdam
Datum konání akce
15. 5. 2017