Popis výsledku v původním jazyce
The energy system consisting of a combined ground-air source heat pump, PV system and seasonal ground storage unit for an energy passive family house has been developed and analysed by computer simulation. The heat pump, during summer operation, transforms the ambient heat to charge the seasonal ground storage with the use of PV electricity only. Winter operation relies on the heat stored under the house and results in low grid electricity consumption. The simulation analysis has shown the significant decrease in the use of the grid electricity needed for the house (the system’s SPF increased from 3.1 for the reference borehole system to about 6.0) and an increase in usability of the local PV electricity production for energy supply (space heating, hot water) in the house. In total, more than 80 % of the energy supply for the house is renewable energy and the specific non-renewable primary energy needs of the house is under 17 kWh.m-2.a-1 (for space heating, hot water and auxiliary energy).
Název v anglickém jazyce
PV and Heat Pump System with a Seasonal Storage for Nearly Zero Energy Building
Popis výsledku anglicky
The energy system consisting of a combined ground-air source heat pump, PV system and seasonal ground storage unit for an energy passive family house has been developed and analysed by computer simulation. The heat pump, during summer operation, transforms the ambient heat to charge the seasonal ground storage with the use of PV electricity only. Winter operation relies on the heat stored under the house and results in low grid electricity consumption. The simulation analysis has shown the significant decrease in the use of the grid electricity needed for the house (the system’s SPF increased from 3.1 for the reference borehole system to about 6.0) and an increase in usability of the local PV electricity production for energy supply (space heating, hot water) in the house. In total, more than 80 % of the energy supply for the house is renewable energy and the specific non-renewable primary energy needs of the house is under 17 kWh.m-2.a-1 (for space heating, hot water and auxiliary energy).
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vytápění, větrání, instalace
ISSN
1210-1389
e-ISSN
—
Svazek periodika
26.
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
328-332
Kód UT WoS článku
—
EID výsledku v databázi Scopus