Radiation Shielding of Personal Protective Equipment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70565813%3A_____%2F14%3A%230000358" target="_blank" >RIV/70565813:_____/14:#0000358 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Radiation Shielding of Personal Protective Equipment
Popis výsledku v původním jazyce
Some samples of personal radiation shielding protective equipment were tested at the National Institute for NBC Protection, Czech Republic in a Radon-aerosol chamber (RAC), which enables direct testing of protective equipment in a radioactive aerosol atmosphere. Main used radionuclides, depositing on non-radioactive aerosol particles into the RAC, were short-term radon decay products, or short-term radionuclides with stable decay products (99mTc, 140La, 24Na ...). Absorbed dose has been measured by TLDs(LiF: Mg Cu, P) and determined by an analyser Harshaw 3500 (producer: ThermoScientific, USA). TLD holders were placed uniformly under and on the surface of individual radiation shielding protective equipment, placed on a testing mannequin, and on covering personal protective clothing against radioactive aerosol contamination. Gamma (and beta) rays attenuation was determined from dose mean values in corresponding parts of protective equipment. Together with testing radiation shielding pr
Název v anglickém jazyce
Radiation Shielding of Personal Protective Equipment
Popis výsledku anglicky
Some samples of personal radiation shielding protective equipment were tested at the National Institute for NBC Protection, Czech Republic in a Radon-aerosol chamber (RAC), which enables direct testing of protective equipment in a radioactive aerosol atmosphere. Main used radionuclides, depositing on non-radioactive aerosol particles into the RAC, were short-term radon decay products, or short-term radionuclides with stable decay products (99mTc, 140La, 24Na ...). Absorbed dose has been measured by TLDs(LiF: Mg Cu, P) and determined by an analyser Harshaw 3500 (producer: ThermoScientific, USA). TLD holders were placed uniformly under and on the surface of individual radiation shielding protective equipment, placed on a testing mannequin, and on covering personal protective clothing against radioactive aerosol contamination. Gamma (and beta) rays attenuation was determined from dose mean values in corresponding parts of protective equipment. Together with testing radiation shielding pr
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
DL - Jaderné odpady, radioaktivní znečištění a kontrola
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20132015105" target="_blank" >VG20132015105: Prevence, připravenost a zmírnění následků těžkých havárií českých jaderných elektráren v souvislosti s novými poznatky zátěžových testů po havárii ve Fukušimě</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů