Rheological characterization of polyolefin composites with reduced flammability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28110%2F12%3A43869024" target="_blank" >RIV/70883521:28110/12:43869024 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/70883521:28610/12:43869024
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.4738465" target="_blank" >http://dx.doi.org/10.1063/1.4738465</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4738465" target="_blank" >10.1063/1.4738465</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rheological characterization of polyolefin composites with reduced flammability
Popis výsledku v původním jazyce
In this work, the low-flammability halogen-free polyolefin composites were characterized with three rheological methods. In the extrusion process of the studied materials the end-products with a dissimilar surface quality were produced. Therefore, the diverse melt flow behaviours evaluated with common rheological techniques were also expected. Nevertheless, the conventional rotational and capillary rheometries were not able to describe the differences between investigated flame retarded composites in optimal way. Thus, the non-conventional rheological die Shark skin, originally designed to detect flow instabilities, was tested as a third possibility in order to better understand rheology of the filled polymer melts. It was found that the Shark skin technique is able to characterize the studied two kind flame retardants composites and can also be helpful to qualify the production bathes with identical additives/polymer formulation.
Název v anglickém jazyce
Rheological characterization of polyolefin composites with reduced flammability
Popis výsledku anglicky
In this work, the low-flammability halogen-free polyolefin composites were characterized with three rheological methods. In the extrusion process of the studied materials the end-products with a dissimilar surface quality were produced. Therefore, the diverse melt flow behaviours evaluated with common rheological techniques were also expected. Nevertheless, the conventional rotational and capillary rheometries were not able to describe the differences between investigated flame retarded composites in optimal way. Thus, the non-conventional rheological die Shark skin, originally designed to detect flow instabilities, was tested as a third possibility in order to better understand rheology of the filled polymer melts. It was found that the Shark skin technique is able to characterize the studied two kind flame retardants composites and can also be helpful to qualify the production bathes with identical additives/polymer formulation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CD - Makromolekulární chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0111" target="_blank" >ED2.1.00/03.0111: Centrum polymerních systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
AIP Conference Proceedings
ISSN
0094-243X
e-ISSN
—
Svazek periodika
1459
Číslo periodika v rámci svazku
2012
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
3
Strana od-do
268-270
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—