Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28110%2F15%3A43873739" target="_blank" >RIV/70883521:28110/15:43873739 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability
Popis výsledku v původním jazyce
Two ethylene-octene copolymers (EOC) with the same melt flow index (MFI = 3 g/10 min) but different octene contents, being 20 and 35 wt % (EOC-20 and EOC-35), were compared with regard to sensitivity to electron beam crosslinking. Dynamic mechanical analysis (DMA) revealed a large influence of the octene content on the storage modulus and the glass transition temperature (T-g) but a smaller influence of irradiation on the properties below melting point (T-m). Rheology at 150 degrees C pointed out largedifferences in samples crosslinked in the 0-60 kGy range and at lower frequencies (0.1-1 Hz). The loss factor tan confirmed that before irradiation the two copolymers were very similar, while after irradiation to 120 kGy, the EOC-35 had considerably lower tan than EOC-20, which corresponds to a better elasticity (or a higher level of crosslinking). A high-temperature creep test showed a considerably lower creep for EOC with a higher octene content. An analysis of the insoluble gel conten
Název v anglickém jazyce
Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability
Popis výsledku anglicky
Two ethylene-octene copolymers (EOC) with the same melt flow index (MFI = 3 g/10 min) but different octene contents, being 20 and 35 wt % (EOC-20 and EOC-35), were compared with regard to sensitivity to electron beam crosslinking. Dynamic mechanical analysis (DMA) revealed a large influence of the octene content on the storage modulus and the glass transition temperature (T-g) but a smaller influence of irradiation on the properties below melting point (T-m). Rheology at 150 degrees C pointed out largedifferences in samples crosslinked in the 0-60 kGy range and at lower frequencies (0.1-1 Hz). The loss factor tan confirmed that before irradiation the two copolymers were very similar, while after irradiation to 120 kGy, the EOC-35 had considerably lower tan than EOC-20, which corresponds to a better elasticity (or a higher level of crosslinking). A high-temperature creep test showed a considerably lower creep for EOC with a higher octene content. An analysis of the insoluble gel conten
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CD - Makromolekulární chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Polymers
ISSN
2073-4360
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
13
Strana od-do
2522-2534
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—