Scanning of electromagnetic radiation for EMC and data security purposes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F08%3A63507502" target="_blank" >RIV/70883521:28140/08:63507502 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Scanning of electromagnetic radiation for EMC and data security purposes
Popis výsledku v původním jazyce
A semi-automatic measurement system and diagnostic tool for localization of radiating parts of electronic devices in near-field was developed. A near-field scanning of electromagnetic emission is performed by the system. Maximal spatial resolution of thescanning is 0.2 mm which is sufficient for exact localization of radiating parts in the most cases. Frequency range of the measurement is from 30 MHz to 3 GHz. The advantage of the system is simplicity of implementation, as it is based entirely on commercially produced devices. The test receiver Rohde & Schwarz ESPI7 was used for the measurement of radiation level. The advantageous functions of the receiver such as fast frequency scan and simultaneous measurement with three detectors was utilized. Thescanning procedure is controlled by a program which leads a user throughout all measurement steps. The program was made in Agilent VEE Pro. Important part of the measurement is processing of the measured data. Therefore, software for effe
Název v anglickém jazyce
Scanning of electromagnetic radiation for EMC and data security purposes
Popis výsledku anglicky
A semi-automatic measurement system and diagnostic tool for localization of radiating parts of electronic devices in near-field was developed. A near-field scanning of electromagnetic emission is performed by the system. Maximal spatial resolution of thescanning is 0.2 mm which is sufficient for exact localization of radiating parts in the most cases. Frequency range of the measurement is from 30 MHz to 3 GHz. The advantage of the system is simplicity of implementation, as it is based entirely on commercially produced devices. The test receiver Rohde & Schwarz ESPI7 was used for the measurement of radiation level. The advantageous functions of the receiver such as fast frequency scan and simultaneous measurement with three detectors was utilized. Thescanning procedure is controlled by a program which leads a user throughout all measurement steps. The program was made in Agilent VEE Pro. Important part of the measurement is processing of the measured data. Therefore, software for effe
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BE - Teoretická fyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings 42nd Annual 2008 IEEE International Carnahan Conference on Security Technology
ISBN
978-1-4244-1816-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Institute for Electrical and Electronic Engineers, Inc.
Místo vydání
New York
Místo konání akce
Prague, Czech Republic
Datum konání akce
16. 10. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce